Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
6120 E 5TH ST
Apply Date:
06/17/2002
Applicant:
VASQUEZ CONSTRUCTION COMPANY INC
Description:
CONDO:TD# 12-98-42 # 136
Contractors:
  • VASQUEZ CONSTRUCTION COMPANY INC

Outstanding Activity Conditions

Permit Number - T02CM02936
Permit Status: C of o
Permit Description: CONDO:TD# 12-98-42 # 136
Total Outstanding Activity Conditions - 1
Date Name
06/17/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM02936
Permit Description: CONDO:TD# 12-98-42 # 136
Total Completed Inspections - 27
Date Description Inspector Results Comments
11/22/2002 EXCAVATION/LAYOUT REBAR & ZON HLEYVA Approved IVRS - Inspection 0000*
11/25/2002 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection 0000*
01/08/2003 STEM WALL/RETAINING WALL HLEYVA Approved IVRS - Inspection 0000*
10/16/2003 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection 0000*/ TEST OK ON UNDERGROUND SOIL SUBJECT TO REVISION. RED LINES ON JOB.
10/17/2003 PLUMBING - YARD WTR LINE/TEST JSTANLEY Approved
10/21/2003 MECHANICAL - UNDERGROUND CWILLIAM Approved IVRS - Inspection 0000*
10/22/2003 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection 0000*/ OK SUB-PANEL FEEDER CONDUIT UNDER SLAB.
10/28/2003 PLUMBING - PROGRESS JSTANLEY Approved IVRS - Inspection 0000*
10/28/2003 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000*
10/28/2003 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*
01/05/2004 ROOF NAILING RSUBA Approved IVRS - Inspection 0000*
01/05/2004 REINFORCED MASONRY PRE-GROUT RSUBA Approved IVRS - Inspection 0000*
02/19/2004 MECHANICAL - INTERMEDIATE JMILITEL Approved OK FOR SHEET ROCK
02/19/2004 PLUMBING - GAS PRESSURE TEST JSTANLEY Approved APPROVED - INSIDE ONLY.
02/19/2004 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*/ TEST ON WASTE VENTS AND WATER OK. PLEASE PROVIDE LETTER OF CHANGE FOR OUR RECORDS.
02/23/2004 FRAMING HLEYVA Approved IVRS - Inspection 0000*
03/16/2004 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*/ 1) APPROVED CONNECTORS TO ATTACH NM CABLES TO PANEL 373.5 2) SUPPORT CABLES ABOVE PANEL 3) OK TO DRYWALL
03/16/2004 SHEET ROCK NAILING HLEYVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/16/2004 STUCCO MESH HLEYVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
10/25/2004 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*/ 1) CONDUITS TO BE AS PER 300.5 18" OF COVER OR CONCRETE ENCASED 3) FILL UNUSED OPENING IN BOXES 4) BOND JUNCTION BOXES 5) BOXES MORE THAN 1/4' IN NON COMBUSTIBLE AND FLUSH IN COMBUSTIBLE WILL NEED APPROVED EXTENDER RING 370.20-METAL NOT APPROVED
01/25/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*APPROVED OK FOR FINAL
01/25/2005 PLUMBING - ABOVE CEILING JSTANLEY Approved
01/25/2005 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection :* LAST INSP ON JOB PLEASE PROVIDE GAS CARD
01/26/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :* APPROVED
01/26/2005 ELECTRIC - CONSTRUCTION POWER RSUBA Approved
02/23/2005 BUILDING - FINAL BSTEVENS Approved IVRS - Inspection :*
08/02/2005 PERMIT FINALED LJACKSON Approved