Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM02936
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/26/2005 | ELECTRIC - INTERMEDIATE | Approved | ||
03/16/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) APPROVED CONNECTORS TO ATTACH NM CABLES TO PANEL 373.5 2) SUPPORT CABLES ABOVE PANEL 3) OK TO DRYWALL | |
02/23/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ OK TO COVER ALL BUT PANEL IN GARAGE NEEDS TO BE IN FIRE RATED ENVELOPE. | |
02/20/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) CLOSET LIGHTS COMPARTMENT FOR SPLICES CANNOT BE COVERED 2) PANEL TO BE ENVELOPED WITH FIRE RATED SHEET ROCK TO INSULATE PANEL WHICH IS IN GARAGE TO OUTSIDE HOUSE 3) FINISH UNTERMINATED WORK |