Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
06/13/2002
Applicant:
GAY, ROBERT CASTLE
Description:
NEW:SFR DEFERRED ICF ( REINFORCED CONCRETE WALL SYSTEM ): PROVIDE SPECIAL INSPECTION AS REQUIRED BY ICBO EVALUATION REPORT, SUBMIT CERTIFICATE FOR SPECIAL INSPECTION PRIOR TO BEGINNING THIS WORK.
Architects:
  • GAY, ROBERT CASTLE

Permit Reviews

Permit Number - T02CM02897
Permit Status: C of o
Permit Description: NEW:SFR DEFERRED ICF ( REINFORCED CONCRETE WALL SYSTEM ): PROVIDE SPECIAL INSPECTION AS REQUIRED BY ICBO EVALUATION REPORT, SUBMIT CERTIFICATE FOR SPECIAL INSPECTION PRIOR TO BEGINNING THIS WORK.
Start Date Submittal Complete Date Status  
06/13/2002 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 07/15/2002 COMPLETED Review Details
07/18/2002 RESUBMITTAL 08/05/2002 COMPLETED Review Details
08/22/2002 RESUBMITTAL 09/03/2002 COMPLETED Review Details
09/18/2002 RESUBMITTAL 10/10/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM02897
Permit Status: C of o
Permit Description: NEW:SFR DEFERRED ICF ( REINFORCED CONCRETE WALL SYSTEM ): PROVIDE SPECIAL INSPECTION AS REQUIRED BY ICBO EVALUATION REPORT, SUBMIT CERTIFICATE FOR SPECIAL INSPECTION PRIOR TO BEGINNING THIS WORK.
Total Outstanding Activity Conditions - 1
Date Name
06/13/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM02897
Permit Description: NEW:SFR DEFERRED ICF ( REINFORCED CONCRETE WALL SYSTEM ): PROVIDE SPECIAL INSPECTION AS REQUIRED BY ICBO EVALUATION REPORT, SUBMIT CERTIFICATE FOR SPECIAL INSPECTION PRIOR TO BEGINNING THIS WORK.
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/21/2002 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection 0000*/ 1) RETAINER FOOTING AROUND SPA AND TREE APPROX 44'
12/03/2002 REINFORCED MASONRY PRE-GROUT MTESTER Approved IVRS - Inspection 0999*/ 1) COULD NOT LOCATE PLANS/PERMITS FOR THIS RETAINING WALL
12/09/2002 STEM WALL/RETAINING WALL RFREIDIN Approved IVRS - Inspection 0000*/ 1) OK GROUT WALL SOLID TO TOP 2) RETAINING WALL FUR POOR
01/14/2003 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*/ 1) SEE NOTE: SITE PLAN HAS WATER METER IN DIFFERENT LOCATION NOT PER PLAN, HAVE PLAN CHANGED 2) INSTALL A PRESS GUAGE ON LINE AT TOP OF HILL
02/06/2003 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved
02/06/2003 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection 0000*
02/10/2003 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
03/03/2003 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*/ 1) VENT FOR SHOWER CODE REQUIRES SIX INCHES ABOVE FLOOD RIM BEFORE GOING HORIZONTAL (LAST RESORT USE SANITARY FITTINGS, TRY TO GET PITCH ON PIPE (THIS SECTION OF PIPE DOESN'T GET WAHSED)
03/11/2003 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
04/08/2003 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*/ 1) MAIN HOUSE
05/09/2003 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
05/09/2003 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) INSTALL ALL LATERAL BRACING ON TRUSS WEB MEMBERS, PER TRUSS SHOP DRAWINGS 2) CHECK BEARING AREA # DECIMAL MEANING 3) INSTALL POSTS FOR HIP BEAM (4 X 6)
07/11/2003 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
07/18/2003 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
07/18/2003 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
07/18/2003 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
07/18/2003 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/ 1) OK TO INSULATE 2) PROTECT ALL PIPES WIRES AT METAL STUDS N/BATH PIPE 3) KITCHEN EXHAUST FAN DUCT TO EXTERIOR 4) NEED STAIRS INSTALLED 5) NEED DRAINS FOR T & P, WATER SOFTNER CONDENSATE 1" AIR GAP 6) LAG BOLTS AT VALLEY BEAM
08/18/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*/ 1) NEED TO SEE JOB CARD AND OLD INSPECTION REPORTS. YOUR PRE/SLAB AND STEM WALL AREN'T ENTERED APPORVE 2) NEED TO SEE FIREPLACE SPECS 3) DRYWALL LID AT W/HTR
10/14/2003 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
03/02/2004 PERMIT FINALED RFREIDIN Approved
03/02/2004 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/02/2004 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/02/2004 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP ON 03/03/04AM
03/02/2004 ELECTRIC - UNDERGROUND RFREIDIN Approved IVRS - Inspection 0000*
03/02/2004 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
T02CM02897 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
None CERT OF OCC VIEW