Permit: T02CM02734
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1951 N WILMOT RD 05
Address NEW:
1951 N WILMOT RD 05
Apply Date:
06/04/2002
Applicant:
METRO PERMIT EXPRESS, INC/STEVE SAILER
Description:
TI:DENTIST OFFICE
Contractors:
- PATHWAY DEVELOPMENTS INC ,
Permit Reviews
Permit Number - T02CM02734
Permit Status: C of o
Permit Description: TI:DENTIST OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/04/2002 | COMMERCIAL TI | 06/12/2002 | COMPLETED |
| 06/12/2002 | RESUBMITTAL | 06/18/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02734
Permit Status: C of o
Permit Description: TI:DENTIST OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/04/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02734
Permit Description: TI:DENTIST OFFICE
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000* 1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED @ TWO WAY C.O. ONLY 3.) OK TO BACKFILL TRENCH. |
| 07/24/2002 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection 0000* 1.) AIR PRESSURE TEST FOR VACUME LINES IS OK 2.) OK TO BACKFILL TRENCH. |
| 08/08/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*AIR PRESSURE TEST FOR VACCUM LINES IS OK.2 |
| 08/16/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | JOB SUPT SAYS INSP'S WERE NOT CALLED FOR!! |
| 08/16/2002 | BUILDING - FINAL | AQUIROZ | Approved | NEED EXITS SIGNS. |
| 10/26/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*OK WALLS. |
| 11/05/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 12/04/2002 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | IVRS - Inspection 0000*OK PARTIAL ABOVE CEILING FRONT AREA ONLY. OK TO CLEAR TEMP POWER FOR TEST SP #14 SUBJECT TO APPROVAL ALL INSPECTORS BLD #5. SPACE #14. |
| 12/04/2002 | BUILDING - TEMP POWER FOR TEST | HLEYVA | Approved | IVRS - Inspection 0000*CLEARANCE PENDING ON ALL INSPECTORS. |
| 12/06/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
| 12/12/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 12/23/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0999*1.) PROVIDE A ROOF JACK AT LOW VOLTAGE PENETRATION THRU ROOF. 2.) MAKE UNIT DATA PLATE W/PROPER HEAT KIT INSTALLED & FUSE ACCORDINGLY. 3.) #8 WIRE NOT ADEQUATE FOR 60 AMP CIRCUIT FROM ELEC. DISCONNECT TO A/C UNIT. |
| 12/23/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0245* ANCHOR 4 PLEX RECEPT. BOXES AT DENTIST WORK STATION. |
| 01/02/2003 | BOILER - AIR TANK | JMILITEL | Approved | IVRS - Inspection 0000*NO BOILER ON SITE. AIR TANK ONLY. |
| 01/03/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 01/03/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 02/25/2003 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 12/19/2003 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 03/03/2004 | PERMIT FINALED | JMILITEL | Approved |