Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
03/26/2002
Applicant:
KIM KIRSCHNER
Description:
TI:OFFICE
Contractors:
  • CARSTENS ELECTRICAL SERVICE INC,*C
  • KLINE HOMES INC , JOHN W

Permit Reviews

Permit Number - T02CM01598
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
03/26/2002 COMMERCIAL TI 04/18/2002 COMPLETED Review Details
04/24/2002 RESUBMITTAL 04/24/2002 COMPLETED Review Details
05/22/2002 REVISION 05/23/2002 COMPLETED Review Details
07/03/2002 REVISION 07/03/2002 COMPLETED Review Details
07/11/2002 REVISION 07/18/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM01598
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
03/26/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM01598
Permit Description: TI:OFFICE
Total Completed Inspections - 21
Date Description Inspector Results Comments
04/25/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
04/25/2002 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection 0000*
04/25/2002 FRAMING AMATHIES Approved IVRS - Inspection 0000*
04/30/2002 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*
04/30/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG. DRAIN 3.) OK TO BACKFILL TRENCH. 4.) NOTE: SEE NOTE #2 ON PREVIOUS INSPECTION. 5.) OVER HEAD WATER DISTRIBUTION IS OK 6.) OK FOR DRYWALL.
04/30/2002 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
05/21/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*1.) SUPPORT EMT CONDUIT PER ART 348 NEC. WITHIN 3' EACH BOX. 2.) DO NOT TIE MC CABLE TO CONDUIT FOR SUPPORT, MUST BE IDIVIDUALLY SUPPORTED 300-11B NEC.
05/21/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0245*
05/22/2002 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*1.) ABOVE CEILING IS OK FOR GRID.
05/28/2002 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000* ALL CORRECTIONS HAVE BEEN MADE OK FOR CEILING TILES.
07/19/2002 FIRE - FINAL LLAKEY Approved
07/19/2002 FIRE SPKLR - FINAL LLAKEY Approved
07/19/2002 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O.
07/19/2002 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
07/22/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
07/22/2002 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection 0000* APPROVED LADDER ON WEST SIDE.
07/22/2002 ELECTRIC - CABLE DROP RMAJUTA Approved
07/24/2002 RIGHT OF WAY - FINAL PWHIDDON Approved
07/24/2002 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
07/24/2002 ENGINEERING - FINAL DROBERTS Approved
07/25/2002 PERMIT FINALED AMATHIES Approved

Documents

File Name Document Type  
C OF O_07-25-2002.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW