Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
02/21/2002
Applicant:
PRESIDIO CONSTRUCTION COMPANY
Description:
TI:RESTAURANT
Architects:
  • PAGE, ROBERT ELWOOD

Permit Reviews

Permit Number - T02CM00984
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date Submittal Complete Date Status  
02/21/2002 COMMERCIAL TI 04/11/2002 COMPLETED Review Details
04/11/2002 RESUBMITTAL 06/10/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM00984
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
02/21/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM00984
Permit Description: TI:RESTAURANT
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/11/2002 RIGHT OF WAY - FINAL PWHIDDON Approved
07/11/2002 ENGINEERING - FINAL DROBERTS Approved
07/12/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) OK TO BACKFILL TRENCH. 4.) NOTE WHAT IS 1 1/2" DRAIN & 1/2 C & H SUPPLY SERVING @K301.1
08/01/2002 PLUMBING - INTERMEDIATE TRINIVJR Approved 1.) WASTE & VENT SYSTEM IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL 4.) NOTE: SUPERINTENDENT WILL VERIFY THAT PLBG. CONTRACTOR WILL INSTALL A SPECIALTY COUPLING WHERE ABS CONNECTS. TO C.I..
08/16/2002 FRAMING AQUIROZ Approved IVRS - Inspection 0000*
08/19/2002 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved 1.) GAS PRESSURE TEST IS OK 2.) RELOCATION OF FLOOR SINK IS OK.
08/28/2002 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
09/27/2002 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*OK TO COVER CEILING.
10/24/2002 PLUMBING - ABOVE CEILING FMCCLURE Approved IVRS - Inspection 0000*
10/24/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
10/24/2002 BUILDING ABOVE CEILING AMATHIES Approved IVRS - Inspection 0000*
10/31/2002 SIGN - FINAL JYBARRA Approved
11/04/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
11/04/2002 MECHANICAL - HOODS JMILITEL Approved
11/04/2002 MECHANICAL - INTERMEDIATE JMILITEL Approved
11/04/2002 PLUMBING - FINAL FMCCLURE Approved IVRS - Inspection 0000*
1.) MUST INSTALL INDIRECT WASTE PROPERLY FOR DISCHARGE OF BACKFLOW PREVENTER AND SODA DISPENSER.
2.) MUST CAULK SINKS IN KITCHEN.
3.) MUST PROVIDE P-TRAP ON INDIRECT WASTE FOR DIP WELL.
4.) MUST TEST & CERTIFY BACKFLOW PREVENTER FOR ICE MACHINE.
11/04/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*OK C OF O.
11/07/2002 FIRE - FINAL LLAKEY Approved
11/12/2002 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection 0000*OK C OF O.
11/14/2002 PERMIT FINALED AQUIROZ Approved
11/14/2002 HEALTH DEPT - FINAL 724-7908 BSIMPSON Approved
11/14/2002 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
11/14/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_11-14-2002.TIF CERT OF OCC VIEW