Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/12/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) OK TO BACKFILL TRENCH. 4.) NOTE WHAT IS 1 1/2" DRAIN & 1/2 C & H SUPPLY SERVING @K301.1 |
| 07/11/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* 1.) ROUGH PLBG. INSTALLED NOT TO PLAN 2.) MUST PROVIDE WATER TEST ON ALL OF NEW SYSTEM. 3.) FLAT VENT WASTE SYSTEM IS ALLOWED ONLY WHEN THERE IS A STRUCTUAL CONDITION THAT IS NOT THE CASE HERE. 4.) WHAT IS 1 1/2" DRAIN & 1/2 C & H SUPPLY. SERVING @ K-30.1 KITCHEN DETAIL? 5.) MUST PROVIDE AIR PRESSURE TEST ON GAS SYSTEM. |