Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
3225 E 27TH ST
Address NEW:
3225 E 27TH ST
Apply Date:
01/11/2002
Applicant:
ALEGRIA HECTOR T & HUGHES-ALEGRI
Description:
ADDITION:BEDROOM/BATHROOM/WASHROOM

Permit Reviews

Permit Number - T02CM00165
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATHROOM/WASHROOM
Start Date Submittal Complete Date Status  
01/11/2002 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 02/27/2002 COMPLETED Review Details
03/26/2002 REVISION 03/26/2002 COMPLETED Review Details
05/27/2003 REVISION 05/27/2003 COMPLETED Review Details
11/18/2002 REVISION 12/12/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM00165
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATHROOM/WASHROOM
Total Outstanding Activity Conditions - 1
Date Name
01/11/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02CM00165
Permit Description: ADDITION:BEDROOM/BATHROOM/WASHROOM
Total Completed Inspections - 15
Date Description Inspector Results Comments
04/07/2002 PLUMBING - GAS PRESSURE TEST MTESTER Approved IVRS - Inspection 0000*
06/04/2002 EXCAVATION/LAYOUT REBAR & ZON MTESTER Approved IVRS - Inspection 0000*
08/15/2002 ELECTRIC - SERVICE RELOCATION FGREER Approved IVRS - Inspection 0000*
09/06/2002 ROOF NAILING FGREER Approved
09/06/2002 EXT METAL CLIPS/EXT SHEATHING FGREER Approved
12/13/2002 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*
12/13/2002 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*/ 1) DRYER CIRCUIT MUST BE 3 WIRE AND GROUND WITH 4 PRONG OUTLET 2) EXHAUST FANS MUST EXHAUST OUTSIDE 3) CONNECT ALL GROUND WIRES IN EACH ELECTRIC BOX AND SECURE WITH A MECHANICAL FASTENER 4) NAIL PROTECT ALL PLUMBING AND ELECTRIC WITHIN 1 1/4" OF STUD SURFACES 5) HEATER CIRCUIT MUST TERMINATE IN AN APPROVED BOX 6) SMOKE DETECTOR IN BEDROOM MUST BE HARD WIRED 7) NEED AN APPROVED FAN BOX NOT CEILING LIGHT
12/13/2002 FRAMING JRIVA Approved IVRS - Inspection 0999*
01/15/2003 MECHANICAL - INTERMEDIATE EDURAZO Approved
03/11/2003 SHEET ROCK NAILING EDURAZO Approved IVRS - Inspection 0000*
03/11/2003 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection 0000*
06/04/2003 PERMIT FINALED FGREER Approved
06/04/2003 PLUMBING - FINAL FGREER Approved IVRS - Inspection 0000*
06/04/2003 ELECTRIC - FINAL FGREER Approved IVRS - Inspection 0000*
06/04/2003 BUILDING - FINAL FGREER Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW