Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/15/2003 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
12/13/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) DRYER CIRCUIT MUST BE 3 WIRE AND GROUND WITH 4 PRONG OUTLET 2) EXHAUST FANS MUST EXHAUST OUTSIDE 3) CONNECT ALL GROUND WIRES IN EACH ELECTRIC BOX AND SECURE WITH A MECHANICAL FASTENER 4) NAIL PROTECT ALL PLUMBING AND ELECTRIC WITHIN 1 1/4" OF STUD SURFACES 5) HEATER CIRCUIT MUST TERMINATE IN AN APPROVED BOX 6) SMOKE DETECTOR IN BEDROOM MUST BE HARD WIRED 7) NEED AN APPROVED FAN BOX NOT CEILING LIGHT