Description:
GRADING:169863CY CUT & 161756CY FILL
Contractors:
  • BORDERLAND CONSTRUCTION COMPANY *C
  • D R HORTON HOMES *C

Permit Reviews

Permit Number - T02BU02488
Permit Status: Expired
Permit Description: GRADING:169863CY CUT & 161756CY FILL
Start Date Submittal Complete Date Status  
06/08/2005 REVISION - GRADING 06/09/2005 COMPLETED Review Details
07/18/2012 REVISION - GRADING 09/25/2012 ACTIVE Review Details
09/12/2002 GRADING 11/26/2002 COMPLETED Review Details
11/26/2002 RESUBMITTAL 12/09/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02BU02488
Permit Status: Expired
Permit Description: GRADING:169863CY CUT & 161756CY FILL
Total Outstanding Activity Conditions - 2
Date Name
09/12/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
11/27/2002 All work is to be performed subject to the requirements of the landscape and native plant preservation plans.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02BU02488
Permite Description: GRADING:169863CY CUT & 161756CY FILL
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/13/2005 GRADING - FINAL N/A Denied 1. Provide revised/as-built: 1.) Grading Plan, 2.) Tentative Plat and 3.) Final Plat, to the City of Tucson's Engineering and Zoning Divisions for review and approval. The plan must show all revisions and modifications. The approved revised/as-built grading plan is required for completion of the final grading inspection.
2. The revised/as-built grading plans that were provided do not show the grading elevations, drainage patterns or property line modifications for Lots 99-101. Drainage from Lots 99-101 is currently flowing across Lot 101 with no provisions for erosion control at the discharge point at the south end of Lot 101.
3. Safety and Health Hazard: Provide barricade railing on both Basin #5 and the drainage channel adjacent to Campana Drive.
4. The invert width of the drainage channel west of Basin 5 is not constructed per plan. The channel width is only 5' of the specified 8'. See Detail A, Page 10.
5. Provide a retaining wall on the vertically cut slope adjacent to the main entrance gate on Firehole River Way. See Detail A, Page 9. Material sloughing off this slope accumulates on the sidewalk.
6. Provide clean drainage transitions behind lots 10, 11 and 12 and remove all excess soil and rubble.
7. Slope grading behind Lots 1, 2 and 5 does not match the plan design. Re-grade the slopes to match the plan and provide soil stabilization.
8. Slope stabilization is not complete. See Grading Note 30 on Page 1 (All slopes steeper than 3:l will be stabilized with stone rip rappping of sculptured rock and installed by approved methods as stated in Development Standard 9-04.3.3). Additional soil stabilization and/or re-vegetation is required at outside perimeters of Lots 99, 75, 74, 71, 52, 42, 41, 40, 39, 37 and at the areas disturbed by the installation of the storm drainage and sanitary sewer pipelines.
9. Repair erosion damage in Basin #1 and remove gravel at inlet to Basin #1. There are (2) basins identified as basin #1 on the north end of this site.
10. Sedimentation indicators in the retention/detention basins have not been constructed to Plan specifications. Provide a revised and approved plan to show the actual size of the pipe that was installed and paint the 4" stripe every 1' with a foot marker as shown on Detail D, Page 12. Verify that elevations match the elevations shown for basin bottoms.
11. Provide an Arizona Registered Professional Engineer's Certified Inspection Report for the drainage and detention/retention facilities.
08/19/2004 LANDSCAPE INSPECTION N/A Not ready for Inspection Monitoring report requested prior to final landscape inspection.

Completed Inspections

Permit Status: Expired
Permit Number: T02BU02488
Permit Description: GRADING:169863CY CUT & 161756CY FILL
Total Completed Inspections - 4
Date Description Inspector Results Comments
07/22/2005 STORMWATER FINAL INSPECTION MRUSSO Approved
07/22/2005 STORMWATER INSTALL OF CONTROLS MRUSSO Approved
07/22/2005 ENGINEERING PRE-CONSTRUCTION MRUSSO Approved
07/22/2005 STORMWATER FOLLOW-UP INSP MRUSSO Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
PAGE1.TIF GRADING PLANS VIEW
PAGE2.TIF GRADING PLANS VIEW
PAGE3.TIF GRADING PLANS VIEW