Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02BU02388
Permit Details
Apply Date:
09/03/2002
Applicant:
TUFF SHED OF TUCSON ''T''
Description:
ADDITION:SHED TD 15-44-91
Contractors:
- TUFF SHED OF TUCSON ''T''
Permit Reviews
Permit Number - T02BU02388
Permit Status: Closed
Permit Description: ADDITION:SHED TD 15-44-91
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/03/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 09/03/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02BU02388
Permit Status: Closed
Permit Description: ADDITION:SHED TD 15-44-91
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/03/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T02BU02388
Permite Description: ADDITION:SHED TD 15-44-91
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
BUILDING - FINAL | N/A | Not Inspected | ||
09/11/2002 | FRAMING | N/A | Denied | IVRS - Inspection 0999*1.) FRAMING DOES NOT CONFORM TO PLAN EG: DOUBLE TOP PLATE, 2 X4 PT BOTTOM PLATE PLYWOOD ON FLOOR ETC. |
09/17/2002 | ROOF NAILING | N/A | Denied | IVRS - Inspection 0999*REVISE PLAN FOR AS BUILT IE A.) 2 X 8 RIDGE BOARD DELETED. B.) 2 X 4 RAFTERS NOT 2 X 6 RAFTERS C.) PLYWOOD TRUSS GUSSETS WITH STAPLES NOT 2 X 4 COLLAR TIES WITH 10d NAILS. ETC... 2.) I AM AWARE OF IBC REQUIREMENT BUT YOUR APPROVED PLAN MUST REFLECT WHAT IS ACTUALLY HERE. 3.) YOU HAVE NOT MET REQUIREMENT FOR EXCEPTION TO IBC 2308.9.2.1. |