Inspection Status: Denied
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/17/2002 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*REVISE PLAN FOR AS BUILT IE A.) 2 X 8 RIDGE BOARD DELETED. B.) 2 X 4 RAFTERS NOT 2 X 6 RAFTERS C.) PLYWOOD TRUSS GUSSETS WITH STAPLES NOT 2 X 4 COLLAR TIES WITH 10d NAILS. ETC... 2.) I AM AWARE OF IBC REQUIREMENT BUT YOUR APPROVED PLAN MUST REFLECT WHAT IS ACTUALLY HERE. 3.) YOU HAVE NOT MET REQUIREMENT FOR EXCEPTION TO IBC 2308.9.2.1. |
| 09/11/2002 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*1.) ROOF JOISTS DO NOT CONFORM TO PLAY EG: H2.5 COLLAR JOISTS RIDGE BEAMS; RAFTER SIZE. |