Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
DUPLEX OTHER
Apply Date:
12/04/2001
Applicant:
LONDER ROBERT M & CHARLOTTE TR
Description:
GAS:PRESSURE TEST

Outstanding Activity Conditions

Permit Number - T01PL02452
Permit Status: Expired
Permit Description: GAS:PRESSURE TEST
Total Outstanding Activity Conditions - 1
Date Name
12/04/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01PL02452
Permite Description: GAS:PRESSURE TEST
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
PLUMBING - GAS PRESSURE TEST N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
12/06/2001 PLUMBING - GAS PRESS TEST FNL N/A Denied IVRS - Inspection 0999*1.) WATER HTR P & T VALVE IS STUCK FROZEN MUST REPLACE AND PROVIDE A UNION IN P & T DRAIN LINE. 2.) MUST USE (3) SHEET METAL SCREWS ON FLU VENT ON ALL JOINTS & VENT CONNECTOR. 3.) MSUT PROVIDE AGA GAS SHUT OFF VALVE AND CAP FOR DRYER OF PERM CAP THIS STUBB. 4.) MUST REMOVE THREAD PROTECTORS ON RISER FOR RANGE AND USE APPROVED COUPLING OR USE A SOLID PIECE OF PIPE AND INSTALL VALVE. 5.) RE TEST SYSTEM 6.) NOTE: AZ STATE REQUIRE A LICENSE PLBG. CONTRACTOR TO DO WORK ON RENTAL PROPERTY FOR GAS LINE.