Inspection Status: Denied
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/06/2001 |
PLUMBING - GAS PRESS TEST FNL |
|
Denied |
IVRS - Inspection 0999*1.) WATER HTR P & T VALVE IS STUCK FROZEN MUST REPLACE AND PROVIDE A UNION IN P & T DRAIN LINE. 2.) MUST USE (3) SHEET METAL SCREWS ON FLU VENT ON ALL JOINTS & VENT CONNECTOR. 3.) MSUT PROVIDE AGA GAS SHUT OFF VALVE AND CAP FOR DRYER OF PERM CAP THIS STUBB. 4.) MUST REMOVE THREAD PROTECTORS ON RISER FOR RANGE AND USE APPROVED COUPLING OR USE A SOLID PIECE OF PIPE AND INSTALL VALVE. 5.) RE TEST SYSTEM 6.) NOTE: AZ STATE REQUIRE A LICENSE PLBG. CONTRACTOR TO DO WORK ON RENTAL PROPERTY FOR GAS LINE. |