Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3024 N DESERT DR
Address NEW:
3024 N DESERT DR
Apply Date:
12/03/2001
Applicant:
ARICO PLUMBING*C
Description:
REPLACE:GAS LINE (APA)
Contractors:
  • ARICO PLUMBING*C

Outstanding Activity Conditions

Permit Number - T01PL02439
Permit Status: Final
Permit Description: REPLACE:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
Date Name
12/03/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T01PL02439
Permit Description: REPLACE:GAS LINE (APA)
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/04/2001 PERMIT FINALED TRINIVJR Approved
12/04/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENT & CAP, P & T. VALVE & DRAIN IS OK 4.) FURNACE IS GAS PACK ON ROOF OK 5.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
12/04/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0999*1.) MUST REMOVE UNION IN LINE ON ROOF AND REPLACE WITH RIGHT & LEFT HAND NIPPLE SEC SECTION: 1211.10 94 UPC. 2.) MUST USE (3) SHEET METAL SCREWS @ VENT COLLAR AND JOINTS FOR WATER HTR FLU VENT 3.) RETEST SYSTEM 10LBS MIN.