Completed Inspections

Permit Status: Closed
Permit Number: T01OT00418
Permit Description: SIGN: 2962
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/24/2001 SIGN SITE REVIEW JYBARRA Approved IVRS - Inspection 0000*
09/26/2001 SIGN SHOP LHANLY Approved IVRS - Inspection 0000*
10/02/2001 SIGN INSPECTION DJOHNSTO Approved IVRS - Inspection 0000*
10/02/2001 SIGN ELECTRIC LHANLY Approved IVRS - Inspection 0999*1.) ALL FITTINGS CONDUIT NIPPLES, ETC MUST BE WRENCH TIGHT. 2.) FLEX CONDUIT MUST BE SECURLY FASTENED ONTO CONDUIT NIPPLE 3.) COUPLINGS ARE NOT LISTED FOR THIS APPLICATION YOU MUST USE FEMALE CONDUIT NIPPLES ON THE ENDS OF ALL THREND PASS THROUGHS. 4.) FLEXIBLE CONDUIT IS REQUIRED TO BE SECURED WITHIN 12' OF EACH END FOR EVERY LENGTH OVER 3' IT MUST ALSO BE SECURED EVERY 3'5.) TRANSFORMER REQUIRED TO BE AS CLOSE AS POSSIBLE" TO NEON. MOUNTING IT ON WALL WOULD BE BETTER.