Permit: T01OT00418

Parcel: 13419042C


Addresses:

7204 E BROADWAY BL


Inspection Status: Approved

Inspection History: SIGN ELECTRIC

Permit Number - T01OT00418

Inspection Description - SIGN ELECTRIC

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2008 SIGN ELECTRIC Approved IVRS - Inspection :*
10/02/2001 SIGN ELECTRIC Denied IVRS - Inspection 0999*1.) ALL FITTINGS CONDUIT NIPPLES, ETC MUST BE WRENCH TIGHT. 2.) FLEX CONDUIT MUST BE SECURLY FASTENED ONTO CONDUIT NIPPLE 3.) COUPLINGS ARE NOT LISTED FOR THIS APPLICATION YOU MUST USE FEMALE CONDUIT NIPPLES ON THE ENDS OF ALL THREND PASS THROUGHS. 4.) FLEXIBLE CONDUIT IS REQUIRED TO BE SECURED WITHIN 12' OF EACH END FOR EVERY LENGTH OVER 3' IT MUST ALSO BE SECURED EVERY 3'5.) TRANSFORMER REQUIRED TO BE AS CLOSE AS POSSIBLE" TO NEON. MOUNTING IT ON WALL WOULD BE BETTER.
09/26/2001 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection 0000*NOT READY FULL CYCLE NEON WALL MOUNT.