Permit: T01OT00418
Permit Details
Apply Date:
08/23/2001
Applicant:
ACCURATE SIGN AND AWNING
Description:
SIGN: 2962
Contractors:
- ACCURATE SIGN AND AWNING
Completed Inspections
Permit Status: Closed
Permit Number: T01OT00418
Permit Description: SIGN: 2962
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2001 | SIGN SITE REVIEW | JYBARRA | Approved | IVRS - Inspection 0000* |
| 09/26/2001 | SIGN SHOP | LHANLY | Approved | IVRS - Inspection 0000* |
| 10/02/2001 | SIGN INSPECTION | DJOHNSTO | Approved | IVRS - Inspection 0000* |
| 10/02/2001 | SIGN ELECTRIC | LHANLY | Approved | IVRS - Inspection 0999*1.) ALL FITTINGS CONDUIT NIPPLES, ETC MUST BE WRENCH TIGHT. 2.) FLEX CONDUIT MUST BE SECURLY FASTENED ONTO CONDUIT NIPPLE 3.) COUPLINGS ARE NOT LISTED FOR THIS APPLICATION YOU MUST USE FEMALE CONDUIT NIPPLES ON THE ENDS OF ALL THREND PASS THROUGHS. 4.) FLEXIBLE CONDUIT IS REQUIRED TO BE SECURED WITHIN 12' OF EACH END FOR EVERY LENGTH OVER 3' IT MUST ALSO BE SECURED EVERY 3'5.) TRANSFORMER REQUIRED TO BE AS CLOSE AS POSSIBLE" TO NEON. MOUNTING IT ON WALL WOULD BE BETTER. |