Permit: T01EL02495
Permit Details
Apply Date:
10/11/2001
Applicant:
ESSNER JAMES
Description:
UPGRADE:ELECTRICAL FORM 60AMP TO 200AMP
Permit Reviews
Permit Number - T01EL02495
Permit Status: Expired
Permit Description: UPGRADE:ELECTRICAL FORM 60AMP TO 200AMP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/11/2001 | ELECTRICAL | 10/11/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01EL02495
Permit Status: Expired
Permit Description: UPGRADE:ELECTRICAL FORM 60AMP TO 200AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/11/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01EL02495
Permite Description: UPGRADE:ELECTRICAL FORM 60AMP TO 200AMP
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2001 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0245*1.) INSTALL SCREWS OR RIVITS TO HOLD ADDRESS LABEL ON SERVICE. 2.) COVER LB AT LEFT SIDE OF SERVICE 3.) NEW SERVICE INSTALLED OVER 24" PATIO WALL IN VIOLATION OF DEDICATED WORKING SPACE. 110-26 N.E.C. 4.) DO NOT SPLICE GROUNDING ELECTRODE CONDUCTOR IN GROUND ROD CLAMP. 250-50 N.E.C. |