Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
2725 E MALVERN ST
Apply Date:
07/05/2001
Applicant:
HERVERT GARY
Description:
UPGRADE:ELECTRICAL 60AMP TO 200AMP

Permit Reviews

Permit Number - T01EL01737
Permit Status: Expired
Permit Description: UPGRADE:ELECTRICAL 60AMP TO 200AMP
Start Date Submittal Complete Date Status  
07/05/2001 ELECTRICAL 07/05/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01EL01737
Permit Status: Expired
Permit Description: UPGRADE:ELECTRICAL 60AMP TO 200AMP
Total Outstanding Activity Conditions - 1
Date Name
07/05/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01EL01737
Permite Description: UPGRADE:ELECTRICAL 60AMP TO 200AMP
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/19/2001 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*1.) BE ADVISED: 1.) THE 1999 ELECT. CODE REQUIRES THE GAS PIPING BE GROUNDED (BOWDED) TO THE GROUNDING SYSTEM GROUND WIRE OR TO THE MAIN PANEL NEUTRAL BAR. YOU MAY AL GROUND THE GAS LINE BY CONNECTING A BONDING JUMPER FROM THE COLD WT PIPE TO THE GAS LINE AT THE WTR. HTR. REF. ART 250 NEC 1999. 2.) THE CIRCUIT BREAKERS MUST BE LABELED/MARKED WITH THE EQUIPMENT OR AREAS THEY SERVE. CORRECT & RECALL FOR FINAL APPROVAL.

Completed Inspections

Permit Status: Expired
Permit Number: T01EL01737
Permit Description: UPGRADE:ELECTRICAL 60AMP TO 200AMP
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/19/2001 ELECTRIC - SERVICE UPGRADE MCAPISTR Approved IVRS - Inspection 0000*
07/19/2001 ELECTRIC - CABLE DROP MCAPISTR Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW