Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01EL01412
Permit Details
Apply Date:
06/04/2001
Applicant:
YOUNG ELECTRIC SIGN COMPANY ,
Description:
SIGN:ELECTRIC:2532
Contractors:
- YOUNG ELECTRIC SIGN COMPANY ,
Outstanding Activity Conditions
Permit Number - T01EL01412
Permit Status: Expired
Permit Description: SIGN:ELECTRIC:2532
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/04/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01EL01412
Permite Description: SIGN:ELECTRIC:2532
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2001 | SIGN ELECTRIC | N/A | Denied | IVRS - Inspection 0999*1.) REPLACE BROKEN P.K. HOUSINGS (LETTER AND POSSIBLY OTHERS) 2.) GTO CABLE MAY BE WITHIN 1 1/2" OF ANY OTHER CABLE OR SIDES OF RACEWAY. 3.) IDENTIFY SIGN CIRCUIT @ SUBPANEL 4.) ALL CONDUIT ON ROOF MUST BE RAISED UP OFF ROOF WITH PROPER BLOCKS (REDWOOD OR UNISTRUT 5.) ALL PULL AND JUNCTION BOXES MUST BE FOR WET LOCATION AND HAVE PROPER GASKETS. |
Completed Inspections
Permit Status: Expired
Permit Number: T01EL01412
Permit Description: SIGN:ELECTRIC:2532
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/08/2001 | SIGN SHOP | LHANLY | Approved | IVRS - Inspection 0000* |
| 07/31/2001 | SIGN INSPECTION | DJOHNSTO | Approved | IVRS - Inspection 0000* |