Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01EL01412


Addresses:

5525 E PIMA ST

Inspection Status: Denied

Inspection History: SIGN ELECTRIC

Date Description Inspector Results Comments
07/30/2001 SIGN ELECTRIC Denied IVRS - Inspection 0999*1.) REPLACE BROKEN P.K. HOUSINGS (LETTER AND POSSIBLY OTHERS) 2.) GTO CABLE MAY BE WITHIN 1 1/2" OF ANY OTHER CABLE OR SIDES OF RACEWAY. 3.) IDENTIFY SIGN CIRCUIT @ SUBPANEL 4.) ALL CONDUIT ON ROOF MUST BE RAISED UP OFF ROOF WITH PROPER BLOCKS (REDWOOD OR UNISTRUT 5.) ALL PULL AND JUNCTION BOXES MUST BE FOR WET LOCATION AND HAVE PROPER GASKETS.