Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
5305 E SPEEDWAY BL
Apply Date:
11/14/2001
Applicant:
ROBERT SMITH
Description:
REMODEL:RESTAURANT 30' x 80' SPACE, METAL STUDS W/ GYP BD
Architects:
  • JOHNS, DAVID F
Contractors:
  • D J WILLIAMSON ENTERPRISES INC

Permit Reviews

Permit Number - T01CM05586
Permit Status: C of o
Permit Description: REMODEL:RESTAURANT 30' x 80' SPACE, METAL STUDS W/ GYP BD
Start Date Submittal Complete Date Status  
01/17/2002 REVISION 01/17/2002 COMPLETED Review Details
11/14/2001 COMMERCIAL TI 11/30/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM05586
Permit Status: C of o
Permit Description: REMODEL:RESTAURANT 30' x 80' SPACE, METAL STUDS W/ GYP BD
Total Outstanding Activity Conditions - 1
Date Name
11/14/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T01CM05586
Permit Description: REMODEL:RESTAURANT 30' x 80' SPACE, METAL STUDS W/ GYP BD
Total Completed Inspections - 17
Date Description Inspector Results Comments
12/04/2001 PLUMBING - PROGRESS TRINIVJR Approved IVRS - Inspection 0000*
12/04/2001 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*
12/04/2001 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*
12/04/2001 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) WATER DISTRIBUTION IS OK 4.) OK FOR DRYWALL & CONCRETE.
12/04/2001 FRAMING AMATHIES Approved IVRS - Inspection 0000*
12/07/2001 SIGN - FINAL JYBARRA Approved
12/14/2001 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
12/14/2001 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
12/17/2001 RIGHT OF WAY - FINAL DROBERTS Approved
12/17/2001 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
12/17/2001 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*NOT READY/CANCEL.
12/18/2001 ENGINEERING - FINAL DROBERTS Approved
12/19/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0999*1.) MUST PROVIDE BACKFLOW PROVENTER FOR ICE MACHINE 007 AND 009 FOR CARBINATED WATER 009 AND HAVE THEM TESTED & CERIFIED PRIOR TO FINAL INSPECTION. 2.) MUST CAULK ALL FIXTURES 3.) WILL REQUIRE A APPROVED DRAWING FOR MOP SINK & PAY CONNECTION FEES 4.) MUST PROVIDE PROPER INDIRECT WASTER SYSTEM FOR DISHWASHER AND SECURE DRAIN TO WALL ABOVE FLOOR.5.) MUST PROVIDE FLOW CONTROL & VENT FOR TRIPLE COMPT. SINK AND PLUMB CONTINUOS WASTE TO CODE. 6.) MUST REPLACE WATER HTR P & T VALVE AND REMOVE FLEX LINE AND PROVIDE UNION. 7.) MUST PROVIDE WRAP FOR H.C. LAVS WASTE & SUPPLYS (ADA) SPEC. 8.) H.C. WATER CLOSET IN MENS RM MUST BE ON OPEN SIDE OF RM (ADA SPECS) 9.) H.C. LAVS MUST HAVE GRID STRAINERS.
01/22/2002 PERMIT FINALED HEALTH Approved
01/24/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*OK C OF O.
01/24/2002 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
01/25/2002 HEALTH DEPT - FINAL 724-7908 HEALTH Approved

Documents

File Name Document Type  
T01CM05586 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
None CERT OF OCC VIEW