Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM05586
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2002 | PLUMBING - FINAL | Approved | ||
| 12/19/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) MUST PROVIDE BACKFLOW PROVENTER FOR ICE MACHINE 007 AND 009 FOR CARBINATED WATER 009 AND HAVE THEM TESTED & CERIFIED PRIOR TO FINAL INSPECTION. 2.) MUST CAULK ALL FIXTURES 3.) WILL REQUIRE A APPROVED DRAWING FOR MOP SINK & PAY CONNECTION FEES 4.) MUST PROVIDE PROPER INDIRECT WASTER SYSTEM FOR DISHWASHER AND SECURE DRAIN TO WALL ABOVE FLOOR.5.) MUST PROVIDE FLOW CONTROL & VENT FOR TRIPLE COMPT. SINK AND PLUMB CONTINUOS WASTE TO CODE. 6.) MUST REPLACE WATER HTR P & T VALVE AND REMOVE FLEX LINE AND PROVIDE UNION. 7.) MUST PROVIDE WRAP FOR H.C. LAVS WASTE & SUPPLYS (ADA) SPEC. 8.) H.C. WATER CLOSET IN MENS RM MUST BE ON OPEN SIDE OF RM (ADA SPECS) 9.) H.C. LAVS MUST HAVE GRID STRAINERS. | |
| 12/17/2001 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION. |