Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
6956 E VERNICE ST
Apply Date:
10/30/2001
Applicant:
QUALIFIED MECHANICAL CONTRACTORS,*C
Description:
REPLACE:GASLINE/BRING WATERHEATER UP TO CODE & ADD GAS FURNACE
Contractors:
  • QUALIFIED MECHANICAL CONTRACTORS,*C

Outstanding Activity Conditions

Permit Number - T01CM05406
Permit Status: Final
Permit Description: REPLACE:GASLINE/BRING WATERHEATER UP TO CODE & ADD GAS FURNACE
Total Outstanding Activity Conditions - 1
Date Name
10/30/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T01CM05406
Permit Description: REPLACE:GASLINE/BRING WATERHEATER UP TO CODE & ADD GAS FURNACE
Total Completed Inspections - 3
Date Description Inspector Results Comments
11/01/2001 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
11/01/2001 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*/ 1) GAS PRESSSURE TEST-OK 2) CANNOT USE FLEX FOR T & P LINE, MUST BE FULL SIZE 3/4" PIPE 3) T & P 90 DEGREE ELBOW AT EXTERIRO IS BELOW GRADE, NEED SMALL DRY WELL 4) REMOVE TAPE AT DOUBLE-SINGLE WALL FLUE, USE SCREWS 5) T & P VALVE STICKS WATER KEEPS RUNNING 6) PLEASE LEAVE PERMIT ON SITE
04/06/2007 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW