Permit: T01CM05351
Permit Details
Apply Date:
10/26/2001
Applicant:
CONTRAVEST PROPERTIES
Description:
SFR:TD#15-07-02
Contractors:
- CONTRAVEST PROPERTIES
Permit Reviews
Permit Number - T01CM05351
Permit Status: C of o
Permit Description: SFR:TD#15-07-02
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/26/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 01/15/2002 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05351
Permit Description: SFR:TD#15-07-02
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2002 | PLUMBING - SEWER HCS CONNECT | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/07/2002 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/07/2002 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | IVRS - Inspection 0000*/ 1) NOTE: BEACAUSE THE NORTH LOT LINE IS GREATER THAN 3' TO THE HOUSE, IT WILL BE NECESSARY TO VERIFY SET BACK AT THE TIME OF PRE-SLAB INSPECTION. PLEASE PROVIDE STRING LINE AT LOT LINE AT PER-SLAB INSPECTION. ALSO A FULL ONE HOUR FIREWALL WILL BE REQUIRED ON THAT SIDE OF HOUSE. GARAGE SOUTH LINE WILL ALSO REQUIRE STRING LINE AT PRE-SLAB AND FIRE WALL ON VERTICAL CONSTRUCTION |
02/14/2002 | ELECTRIC - UFER | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/14/2002 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/14/2002 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/22/2002 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection 0000* |
03/27/2002 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/27/2002 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/03/2002 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/03/2002 | PLUMBING - GAS PRESSURE TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/03/2002 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/03/2002 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/03/2002 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0000* |
05/30/2002 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
07/09/2002 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection 0000*/ 1) NOTE: 3 COAT STUCCO REQUIRED < 3' SIDE OF HOUSE AND GARAGE |
11/06/2002 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection 0000* |
11/13/2002 | PERMIT FINALED | ROHAVER | Approved | |
11/13/2002 | MECHANICAL - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
11/13/2002 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
11/13/2002 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
11/13/2002 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection 0000*/ 1) REINSPECT |