Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
759 S 9TH AV
Apply Date:
10/22/2001
Applicant:
N/A
Description:
TOWNHOME:TD#15-12-92
Contractors:
  • BECKLIN COMPANY L L C

Permit Reviews

Permit Number - T01CM05263
Permit Status: C of o
Permit Description: TOWNHOME:TD#15-12-92
Start Date Submittal Complete Date Status  
10/22/2001 RESIDENTIAL BLDG/ZONING/FLOOD 10/22/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM05263
Permit Status: C of o
Permit Description: TOWNHOME:TD#15-12-92
Total Outstanding Activity Conditions - 1
Date Name
10/22/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T01CM05263
Permit Description: TOWNHOME:TD#15-12-92
Total Completed Inspections - 29
Date Description Inspector Results Comments
01/18/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
01/18/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
03/28/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*1.) 4" ABS SEWER FROM TWO WAY CLEAN OUT TO WITHIN 12" OF MAIN IN 9TH AV OK WATER TEST OK OK TO BACKFILL. 2.) SEWER MAININ STREET COLLAPSED IN SEVERAL AREAS COUNTRY WASTEWATER TO REPLACE THIS BAD SECTION. 3.) IF COUNTY WONT MAKE FINAL CONNECTION CONTACT THIS INSPECTOR TO INSPECT FINAL CONNECTION.
03/28/2002 PLUMBING - GAS PRESS TEST FNL RMYERS Approved
05/13/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
05/13/2002 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection 0000*
05/22/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*
05/23/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*NOTES! SEE INSP. PAPERS FOR 775 S. 9TH.
05/28/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*1.) 1" PVC YARDWATE, FROM METER, TO COPPER TRANSITION OK 2.) TRANISITION FITTINGS OK 3.) PRESSURE TEST OK 4.) OK TO BACKFILL.
05/30/2002 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
05/31/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
05/31/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
06/07/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*1.) CORRECTIONS MADE OK 2.) ABS WATER TEST OK PEX PRESSURE TEST OK 3.) CLOSETT FLANGES OK 3.) TUBS OK 4.) OK TO COVER ALL AREAS.
06/12/2002 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*FIRE WALL SHEATHING @ NORTH END FOR 0 LOT LINE CONST.
06/12/2002 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection 0000*
06/14/2002 ELECTRIC - TEMPORARY SERVICE JORTA Approved
06/14/2002 ELECTRIC - TEMPORARY SERVICE JORTA Approved IVRS - Inspection 0999*
06/14/2002 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000*
06/14/2002 ELECTRIC - UFER JORTA Approved
07/31/2002 MECHANICAL - TEMP PWR FOR TEST CWILLIAM Approved
07/31/2002 PLUMBING - TEMP POWER FOR TEST RMYERS Approved IVRS - Inspection 0000*OK FOR TEMPORARY POWER FOR TESTING.
07/31/2002 BUILDING - TEMP POWER FOR TEST LHANLY Approved IVRS - Inspection 0000*
08/01/2002 ELECTRIC - TEMP POWER FOR TEST JORTA Approved IVRS - Inspection 0000*
08/09/2002 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
09/12/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) PLUMBING FINAL OK 2.) CONTRACTOR TO CUT DOWN EXTERIOR CLEAN OUTS 3.) OK FOR C OF O PENDING ANY OTHER INSPECTION 4.) MECHANICAL INSPECTORS TO RELEASE GAS.
09/13/2002 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*
09/17/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
09/17/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
09/18/2002 PERMIT FINALED RMYERS Approved