Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
4721 E CAMP LOWELL DR
Apply Date:
09/27/2001
Applicant:
N/A
Description:
OFFICE:MEDICAL
Contractors:
  • VENTURE WEST INC

Permit Reviews

Permit Number - T01CM04833
Permit Status: C of o
Permit Description: OFFICE:MEDICAL
Start Date Submittal Complete Date Status  
03/19/2002 REVISION 04/15/2002 COMPLETED Review Details
09/27/2001 3RD PARTY REVIEW-COMMERCIAL 11/30/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM04833
Permit Description: OFFICE:MEDICAL
Total Completed Inspections - 35
Date Description Inspector Results Comments
12/31/2001 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*APPROVED.
12/31/2001 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
01/08/2002 STEM WALL/RETAINING WALL AMATHIES Approved IVRS - Inspection 0000*
01/28/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2) HCS CONNECTION OF BLDG. SEWER IS OK 3.) OK TO BACKFILL TRENCH. 4.) NOTE: WILL REQUIRE A REVISED & APPROVED DRAWING FOR THE ADDITION OF FLOOR SINK & PAY FOR CONNECTIONS FEES PRIOR TO NEXT INSPECTION.
02/05/2002 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*
02/25/2002 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved
02/28/2002 ROOF NAILING AQUIROZ Approved IVRS - Inspection 0000*
03/04/2002 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection 0000*
04/19/2002 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) WASTE & VENT SYSTEM IS OK 3.) OVERHEAD WATER DISTRIBUTION ISOK 4.) OK FOR DRYWALL UPON BLDG. INSPECTORS APPROVAL. 5.) NOTE CLOSET RINGS HAVE NOT BEEN INSTALLED @ THIS TIME.
05/03/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
05/21/2002 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
06/17/2002 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*OK FOR CEILING TILES.
06/17/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
06/20/2002 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection 0000*OK CABLE DROP, BUT NO POWER YET. NOTE TO CONTR. PLEASE SEE SHEET FOR TEMP POWER FOR TEST.
07/05/2002 FRAMING AMATHIES Approved
07/09/2002 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved IVRS - Inspection 0000*
07/09/2002 PLUMBING - TEMP POWER FOR TEST TRINIVJR Approved IVRS - Inspection 0000* 1.) WATER DISTRIBUTION HAS BEEN BONDED. 2.) NO GAS SYSTEM IN BLDG.
07/09/2002 ELECTRIC - TEMP POWER FOR TEST DSANTACR Approved IVRS - Inspection 0000*OK TO CLEAR TEMP POWER FOR TEST 4721 E. CAMP LOWELL SUITES METER 1 & 2.
07/09/2002 BUILDING - TEMP POWER FOR TEST AQUIROZ Approved IVRS - Inspection 0000*
07/24/2002 ENGINEERING - FINAL DROBERTS Approved
07/26/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
07/26/2002 FIRE - FINAL LTHOMAS Approved
07/26/2002 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) PLBG FINAL I SOK 2.) OK FOR C OF O.
07/26/2002 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved
07/26/2002 PLUMBING - INTERMEDIATE TRINIVJR Approved
07/26/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*OK C OF O OK GEN. TEST.
07/29/2002 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection 0000* OK C OF O.
07/29/2002 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection 0000*
07/29/2002 STUCCO MESH AQUIROZ Approved IVRS - Inspection 0000*
08/02/2002 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
08/02/2002 FIRE SPKLR - FINAL LTHOMAS Approved
08/02/2002 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
08/02/2002 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
08/02/2002 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/05/2002 RIGHT OF WAY - FINAL PWHIDDON Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_08-05-2002.TIF CERT OF OCC VIEW