Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address NEW:
129 N COLUMBUS BL
Apply Date:
09/06/2001
Applicant:
BRISCOE KATHY M
Description:
ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE

Permit Reviews

Permit Number - T01CM04408
Permit Status: Expired
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Start Date Submittal Complete Date Status  
03/20/2002 REVISION 03/20/2002 COMPLETED Review Details
09/06/2001 RESIDENTIAL BLDG/ZONING/FLOOD 09/19/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM04408
Permit Status: Expired
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Outstanding Activity Conditions - 1
Date Name
09/06/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01CM04408
Permite Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
07/11/2002 BUILDING - FINAL N/A Denied IVRS - Inspection 0992*/ 1) BATTERY OPERATED SMOKE DETECTOR REQUIRED IN EVERY BEDROOM AND ONE IN HALL 2) ELECTRIC WIRE ON OUTSIDE MUST TERMINATE IN AN APPROVED BOX 3) INSTALL A STOOP OUTSIDE ENTRY DOOR. DOOR WIDTH BY 3 FEET 4) SEAL FREEZE BOARD HOLES 5) OUTSIDE REQUIRES GFCI OUTLET
07/11/2002 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0992*

Completed Inspections

Permit Status: Expired
Permit Number: T01CM04408
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/19/2001 FRAMING JRIVA Approved IVRS - Inspection 0999*/ 1) UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE MUST HAVE TREATED SILL PLATE 2) MAXIMUM ALLOWED SPAN BETWEEN STUDS IS 16" 3) WINDOW AND DOOR HEADERS MUST BE SUPPORTED BY TRIMMER STUDS 4) 2 X HEADERS NOT ALLOWED TO BE INSTALLED IN THE FLAT 5) SILL PLATES MUST BE PROPERLY ANCHORED WITH 1/2" ANCHOR BOLTS AT 12" FROM ENDS OF SPLICES 6) REPLACED FIR POSTS CANNOT BE ENCASED IN CONCRETE 7) ALL BEAM SPLICES MUST BEAR ON STRUCTUAL MEMBERS 8) ORIGINAL BEARING WALL AT NORTH END OF ADDITION HAS BEEN REMOVED. 5 OR 6 RAFTERS OF ORIGNAL HOUSE AND PORCH ARE BEARING ON UNKNOWN STRUCTURE EXPOSE 9) REMOVE ALL DRYWALL ON ADDITION CEILING 10) THIS ADDITION IS ADDED LIVING SPACE. NOT STORAGE, REVISE PLAN 11) REVISE PLAN FOR ADDED ELECTRIC. YOU REQUIRE HEAT IN THIS AREA ALSO. YOU NEED A COMPLETE SET OF PLANS INCLUDING FIREPLACE
03/14/2002 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0000*
03/22/2002 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
06/18/2002 STUCCO MESH JRIVA Approved IVRS - Inspection 0000*