Permit: T01CM04408
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
129 N COLUMBUS BL
Address NEW:
129 N COLUMBUS BL
Apply Date:
09/06/2001
Applicant:
BRISCOE KATHY M
Description:
ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Permit Reviews
Permit Number - T01CM04408
Permit Status: Expired
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/20/2002 | REVISION | 03/20/2002 | COMPLETED |
| 09/06/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 09/19/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04408
Permit Status: Expired
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/06/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01CM04408
Permite Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2002 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0992*/ 1) BATTERY OPERATED SMOKE DETECTOR REQUIRED IN EVERY BEDROOM AND ONE IN HALL 2) ELECTRIC WIRE ON OUTSIDE MUST TERMINATE IN AN APPROVED BOX 3) INSTALL A STOOP OUTSIDE ENTRY DOOR. DOOR WIDTH BY 3 FEET 4) SEAL FREEZE BOARD HOLES 5) OUTSIDE REQUIRES GFCI OUTLET |
| 07/11/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0992* |
Completed Inspections
Permit Status: Expired
Permit Number: T01CM04408
Permit Description: ENCLOSE PORCH TO FAMILY ROOM/FIREPLACE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2001 | FRAMING | JRIVA | Approved | IVRS - Inspection 0999*/ 1) UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE MUST HAVE TREATED SILL PLATE 2) MAXIMUM ALLOWED SPAN BETWEEN STUDS IS 16" 3) WINDOW AND DOOR HEADERS MUST BE SUPPORTED BY TRIMMER STUDS 4) 2 X HEADERS NOT ALLOWED TO BE INSTALLED IN THE FLAT 5) SILL PLATES MUST BE PROPERLY ANCHORED WITH 1/2" ANCHOR BOLTS AT 12" FROM ENDS OF SPLICES 6) REPLACED FIR POSTS CANNOT BE ENCASED IN CONCRETE 7) ALL BEAM SPLICES MUST BEAR ON STRUCTUAL MEMBERS 8) ORIGINAL BEARING WALL AT NORTH END OF ADDITION HAS BEEN REMOVED. 5 OR 6 RAFTERS OF ORIGNAL HOUSE AND PORCH ARE BEARING ON UNKNOWN STRUCTURE EXPOSE 9) REMOVE ALL DRYWALL ON ADDITION CEILING 10) THIS ADDITION IS ADDED LIVING SPACE. NOT STORAGE, REVISE PLAN 11) REVISE PLAN FOR ADDED ELECTRIC. YOU REQUIRE HEAT IN THIS AREA ALSO. YOU NEED A COMPLETE SET OF PLANS INCLUDING FIREPLACE |
| 03/14/2002 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0000* |
| 03/22/2002 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 06/18/2002 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection 0000* |