Permit: T01CM04117
Permit Details
Apply Date:
08/22/2001
Applicant:
ARM CONSTRUCTION
Description:
ADDITION:FAMILY ROOM
Contractors:
- ARM CONSTRUCTION
Permit Reviews
Permit Number - T01CM04117
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/22/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 08/22/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04117
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/22/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM04117
Permit Description: ADDITION:FAMILY ROOM
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2001 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 09/13/2001 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/05/2001 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/05/2001 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 12/07/2001 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 12/07/2001 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 12/07/2001 | FRAMING | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) SEAL OFF GAPS AT DRAFT STOP, FIREPLACE CHIMNEY 2) PER FIREPLACE SPECS ONLY LICENSED INSTALLED TO DO WORK PLEASE LEAVE INFORMATION AS TO WHO INSTALLED FIREPLACE 3) OLD PORCH LITE, POWER SOURCE TO BE REMOVED OR EXTEND INSTALL BLANK COVER PLATE 4) BEND ROMEX AWAY FROM LIGHT CANS 5) DUCT WORK NOT INSTALLED YET 6) PLATE ANCHOR BOLTS WERE TO BE 1/2", HOW MUCH EMBEDMENT DO YOU HAVE WITH 3/8" BOLTS ? 7) QUESTION: CAN'T FIND VENT THAT IS INSTALLED AT EXTERIOR WALL FOR FIREPLACE, IN INSTALLATION BOOKLET. WHATS IT FOR ? 8) HOME RUNS NOT INSTALLED YET 9) SLANTED CRICKET AT ROOF GRADE CHANGE NOT UP TIGHT TO FLAT 2 X 4'S |
| 02/21/2002 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/25/2002 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/25/2002 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/25/2002 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) ROUND DUCT TO BE SUPPORTED, INSULATED AND NEED A ROOF JACK 2) J-BOX NOT INSTALLED CORRECTLY ON ROOF TWO CIRCUIT 3) ROOF JACK FOR PLASTIC CONDUIT 2" SCH 80 REQUIRED-ROOF AND PARAPET 4) ALL DUCTS TO BE SEAL CORRECTLY 5) THERMOSTAT WIRE TO BE IN CONDUIT 6) CONDUIT AND GAS LINES TO BE BLOCKED AND SECURED TO ROOF 7) NEED T3P FOR WATER HEATER 8) GAS PIPING DIAGRAM LEFT ON SITE 105,000 BTU=95 CFH TOTAL RUN OF 153-NEED 1" PIPE TO FIREST TEG 1" TRUNK=158 CFH 9) NEED STUCCO CARD 10) CHECK FIREPLACE INSTALLATION BOOK FOR FLUE AT ABOVE PARAPET 11) CHECK 4 #6 WIRES IN 1/2 CONDUIT 40,000 ROOF PACK HT/COOLING |
| 06/09/2003 | PERMIT FINALED | JRIVA | Approved | |
| 06/09/2003 | STUCCO MESH | JRIVA | Approved |