Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
4914 E 4TH ST
Address NEW:
4914 E 4TH ST
Apply Date:
08/22/2001
Applicant:
ARM CONSTRUCTION
Description:
ADDITION:FAMILY ROOM
Contractors:
  • ARM CONSTRUCTION

Permit Reviews

Permit Number - T01CM04117
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM
Start Date Submittal Complete Date Status  
08/22/2001 RESIDENTIAL BLDG/ZONING/FLOOD 08/22/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM04117
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM
Total Outstanding Activity Conditions - 1
Date Name
08/22/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T01CM04117
Permit Description: ADDITION:FAMILY ROOM
Total Completed Inspections - 13
Date Description Inspector Results Comments
09/13/2001 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
09/13/2001 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
11/05/2001 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
11/05/2001 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
12/07/2001 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/07/2001 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/07/2001 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/ 1) SEAL OFF GAPS AT DRAFT STOP, FIREPLACE CHIMNEY 2) PER FIREPLACE SPECS ONLY LICENSED INSTALLED TO DO WORK PLEASE LEAVE INFORMATION AS TO WHO INSTALLED FIREPLACE 3) OLD PORCH LITE, POWER SOURCE TO BE REMOVED OR EXTEND INSTALL BLANK COVER PLATE 4) BEND ROMEX AWAY FROM LIGHT CANS 5) DUCT WORK NOT INSTALLED YET 6) PLATE ANCHOR BOLTS WERE TO BE 1/2", HOW MUCH EMBEDMENT DO YOU HAVE WITH 3/8" BOLTS ? 7) QUESTION: CAN'T FIND VENT THAT IS INSTALLED AT EXTERIOR WALL FOR FIREPLACE, IN INSTALLATION BOOKLET. WHATS IT FOR ? 8) HOME RUNS NOT INSTALLED YET 9) SLANTED CRICKET AT ROOF GRADE CHANGE NOT UP TIGHT TO FLAT 2 X 4'S
02/21/2002 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
11/25/2002 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
11/25/2002 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
11/25/2002 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*/ 1) ROUND DUCT TO BE SUPPORTED, INSULATED AND NEED A ROOF JACK 2) J-BOX NOT INSTALLED CORRECTLY ON ROOF TWO CIRCUIT 3) ROOF JACK FOR PLASTIC CONDUIT 2" SCH 80 REQUIRED-ROOF AND PARAPET 4) ALL DUCTS TO BE SEAL CORRECTLY 5) THERMOSTAT WIRE TO BE IN CONDUIT 6) CONDUIT AND GAS LINES TO BE BLOCKED AND SECURED TO ROOF 7) NEED T3P FOR WATER HEATER 8) GAS PIPING DIAGRAM LEFT ON SITE 105,000 BTU=95 CFH TOTAL RUN OF 153-NEED 1" PIPE TO FIREST TEG 1" TRUNK=158 CFH 9) NEED STUCCO CARD 10) CHECK FIREPLACE INSTALLATION BOOK FOR FLUE AT ABOVE PARAPET 11) CHECK 4 #6 WIRES IN 1/2 CONDUIT 40,000 ROOF PACK HT/COOLING
06/09/2003 PERMIT FINALED JRIVA Approved
06/09/2003 STUCCO MESH JRIVA Approved