Permit: T01CM03890
Permit Details
Apply Date:
08/08/2001
Applicant:
ROCKING M CONSTRUCTION INC ,
Description:
DUPLEX:TD#15-03-77
Contractors:
- ROCKING M CONSTRUCTION INC ,
Permit Reviews
Permit Number - T01CM03890
Permit Status: Final
Permit Description: DUPLEX:TD#15-03-77
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/08/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 08/08/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM03890
Permit Description: DUPLEX:TD#15-03-77
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2001 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000*THIS WASTE & RENT SYSTEM WILL REQUIRE A GRAVITY WATER TEST AGAIN AT TIME OF INTER MEDIATE PLUMBING INSPECTIONS |
| 08/21/2001 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 08/21/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
| 08/21/2001 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000*1.) WIDEN FOOTING BETWEEN HOUSE AND GARAGE TO 16" CLEAN OUT EXTERIOR FOOTING. |
| 09/18/2001 | ROOF NAILING | DWITT | Approved | IVRS - Inspection 0000* |
| 09/18/2001 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved | IVRS - Inspection 0000* |
| 10/10/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 10/17/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR SHEETROCK. |
| 10/17/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
| 11/01/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) REVISED & APPROVED DRAWING FOR STUDOR VENT FOR KITCHEN SINK IS OK 2.) OK FOR DRYWALL. |
| 11/01/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* |
| 11/01/2001 | STUCCO MESH | DWITT | Approved | IVRS - Inspection 0000*AS NOTED PROVIDE STUCCO CERTIFICATE AT TIME OF BLDG. FINAL. |
| 11/06/2001 | PLUMBING - YARD WTR LINE/TEST | FMCCLURE | Approved | IVRS - Inspection 0000*OK TO COVER SEWER COVERED. |
| 11/15/2001 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0999*1.) MUST STRAP DISHWASHER DRAIN HOSE AS HIGH AS POSSIBLE TO BOTTOM OF COUNTER TOP WITH APPROVED STRAP. 2.) WATER CLOSET IN FRONT UNIT DOSE NOT MEET THE MIN. SIDE CLEARANCE OF 15" TO OF CLOSET 3.) MUST CAULK KITCHEN SINKS. |
| 12/28/2001 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | ELECTRIC - FINAL | MCAPISTR | Approved | 1.) THE NE CODE PROHIBITS THE USE OF EXPOSED LIGHT BULBS IN CLOTHES CLOSETS. THE RECESSED LIGHT FIXTURES IN THE CLOSETS WILL HAVE TO E TRIMMED WITH AT TRIM THAT WILL COVER THE LIGHT BULB. ELECTRICIAN CORRECTED ON SITE. |
| 12/28/2001 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000*1.) PROVIDE THE APPROVED FINAL INSPECTIONS AS ENUMERATED ON THE LIST OF REQUIRED INSPECTIONS. 2. PROVIDE THE APPROVED PLANS |
| 01/04/2002 | PERMIT FINALED | DWITT | Approved | |
| 01/04/2002 | MECHANICAL - FINAL | CWILLIAM | Approved |