Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM03849
Permit Details
Apply Date:
08/06/2001
Applicant:
STICKLEY PANNO GROUP
Description:
TI:OFFICE & PAINT BOOTH
Architects:
- STICKLEY PANNO GROUP
Contractors:
- LANG CONSTRUCTION INC , W J
Permit Reviews
Permit Number - T01CM03849
Permit Status: C of o
Permit Description: TI:OFFICE & PAINT BOOTH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/06/2001 | COMMERCIAL TI | 09/10/2001 | COMPLETED |
09/10/2001 | RESUBMITTAL | 09/21/2001 | COMPLETED |
09/21/2001 | RESUBMITTAL | 10/03/2001 | COMPLETED |
10/24/2001 | REVISION | 10/24/2001 | COMPLETED |
10/24/2001 | REVISION | 11/09/2001 | COMPLETED |
10/29/2001 | REVISION | 10/31/2001 | COMPLETED |
11/30/2001 | REVISION | 12/03/2001 | COMPLETED |
12/11/2001 | REVISION | 12/13/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM03849
Permit Status: C of o
Permit Description: TI:OFFICE & PAINT BOOTH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/06/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03849
Permit Description: TI:OFFICE & PAINT BOOTH
Total Completed Inspections - 36
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/19/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
10/29/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
10/29/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* |
11/05/2001 | SHEET ROCK NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
11/05/2001 | BUILDING PRE-SLAB | EMONAHAN | Approved | IVRS - Inspection 0000* |
11/19/2001 | FRAMING | EMONAHAN | Approved | IVRS - Inspection 0000* |
12/04/2001 | BUILDING - FINAL | EMONAHAN | Approved | IVRS - Inspection 0000* |
12/04/2001 | STEM WALL/RETAINING WALL | EMONAHAN | Approved | IVRS - Inspection 0000* |
12/05/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
12/05/2001 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
12/05/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
12/05/2001 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000* |
12/05/2001 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000*OK TO TILE ROOMS MANAGER OFFICE, COFFEE RM, RECEPTION. |
12/07/2001 | BUILDING ABOVE CEILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
12/11/2001 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
12/11/2001 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection 0000*TEST OK. PROVIDE LISTING AS PER REQUEST 12-5-01 |
12/19/2001 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
12/19/2001 | PLUMBING - TEMP POWER FOR TEST | JSTANLEY | Approved | IVRS - Inspection 0000*TEMP GAS OK SUBJECT TO OTHER INSP. MAXITROL MODEL RVGI LISTING ON JOB LAST INSP ON JOB PLEASE PROVIDE GAS CARD. |
12/19/2001 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection 0000*SEE ATTACHED COPIES OF E.T.L LISTING REPORT FOR SPRAY BOOTH. |
12/21/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | FOR FINAL BOOTH PAPER WK. VENT REGULATORS,ETC. |
12/27/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
12/27/2001 | FIRE - FINAL | FIRE | Approved | |
12/27/2001 | FIRE SPKLR - FINAL | FIRE | Approved | NED OUTSIDE PIPE PAINTED, NEED LOCK/CHAIN ON CONTROL UNS (3) SPARE HD BOX MOUNTED/FULL CALC PLATE |
12/28/2001 | ENGINEERING - FINAL | DROBERTS | Approved | |
12/28/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | |
12/30/2001 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*OK SPRAY BOOTH POWER. 2.) OK TO CLOSE PANELS "HD" & "LD" |
01/06/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*OK FINAL. |
01/07/2002 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000* |
01/08/2002 | RIGHT OF WAY - FINAL | ENGINEER | Approved | |
01/08/2002 | BUILDING - TEMP POWER FOR TEST | EMONAHAN | Approved | |
01/09/2002 | PERMIT FINALED | EMONAHAN | Approved | |
01/09/2002 | FIRE SPKLR - OH PIPING & HYDRO | FIRE | Approved | |
01/09/2002 | FIRE SPKLR - UG PIPING FLUSH | FIRE | Approved | |
01/09/2002 | FIRE SPKLR - UG, PIPING, HYDRO | FIRE | Approved | |
01/09/2002 | PLUMBING - PROGRESS | FMCCLURE | Approved |