Permit: T01CM03758
Permit Details
Apply Date:
08/01/2001
Applicant:
BURLINI & SILBERSCHLAG LTD
Description:
TI:RETAIL
Contractors:
- TRI WEST DEVELOPMENT LLC
Permit Reviews
Permit Number - T01CM03758
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/01/2001 | 3RD PARTY COMMERCIAL TI | 09/05/2001 | COMPLETED |
09/26/2001 | REVISION | 09/26/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03758
Permit Description: TI:RETAIL
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/07/2001 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
09/19/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000*DUPLICATE ALREADY I.V.R. |
10/19/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK TO SHEETROCK RESTROOMS PHARMACY |
11/16/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
12/12/2001 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR TEMP C OF O. |
12/18/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
12/18/2001 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) THIS INSPECTION IS FOR OVENS IN BAKERY AND DELI. |
12/20/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
12/20/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) MUST PROVIDE C.O. FOR COMBO WASTE & VENT SYSTEM @ VENTS. 2.) MUST PROVIDE DRAIN FOR BACKFLOW PREVENTER @ SODA MACHINE. 3.) MUST HAVE ALL BACKFLOW PREVENTERS TESTED & CERTIFIED WITHIN BLDG. PRIOR TO FINAL INSP.4.) MUST USE DIRECTIONAL FITTINGS ON ALL CONTINUOUS WASTE. 5.) WOMENS H.C. WATER CLOSET MUST BE @ 18" FROM SIDE WALL AS PER APPROVAL ELEVATION DRAWING (ADA) SPEC. 6.) EXPOSE C.O. FOR PRODUCE SINK 7.) MENS WATER CLOSET DOSE NOT MEET MIN SIDE CLEARANCE OF 15" TO FROM SIDE WALL 8.) OTHER PLBG. CONTACTOR NOT FINISHED WITH RELOCATION OF SINK IN BAKERY. 9.) MUST CAULK ALL FIXTURES & DRINKING FOUNTAIN. |
12/26/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) ALL CORRECTIONS HAVE BEEN MADE.3.) OK FOR C OF O. 4.) U.C.C. HAS BEEN GIVEN TO JOB SUPERINTENDENTS |
12/27/2001 | ENGINEERING - FINAL | DROBERTS | Approved | |
12/28/2001 | PERMIT FINALED | DWITT | Approved | |
12/28/2001 | FIRE SPKLR - FINAL | FIRE | Approved | |
12/28/2001 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/28/2001 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | |
12/28/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | |
12/28/2001 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/28/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/28/2001 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/28/2001 | ELECTRIC - UFER | MCAPISTR | Approved | |
12/28/2001 | BUILDING - FINAL | DWITT | Approved | |
12/28/2001 | SHEET ROCK NAILING | DWITT | Approved | |
12/28/2001 | BUILDING ABOVE CEILING | DWITT | Approved | |
12/28/2001 | ROOF NAILING | DWITT | Approved | |
12/28/2001 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved | |
12/28/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved |