Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
08/01/2001
Applicant:
BURLINI & SILBERSCHLAG LTD
Description:
TI:RETAIL
Contractors:
  • TRI WEST DEVELOPMENT LLC

Permit Reviews

Permit Number - T01CM03758
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date Submittal Complete Date Status  
08/01/2001 3RD PARTY COMMERCIAL TI 09/05/2001 COMPLETED Review Details
09/26/2001 REVISION 09/26/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM03758
Permit Description: TI:RETAIL
Total Completed Inspections - 26
Date Description Inspector Results Comments
09/07/2001 PLUMBING - SEWER HCS CONNECT FMCCLURE Approved IVRS - Inspection 0000*
09/19/2001 BUILDING PRE-SLAB DWITT Approved IVRS - Inspection 0000*DUPLICATE ALREADY I.V.R.
10/19/2001 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*OK TO SHEETROCK RESTROOMS PHARMACY
11/16/2001 FRAMING DWITT Approved IVRS - Inspection 0000*
12/12/2001 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection 0000*OK FOR TEMP C OF O.
12/18/2001 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
12/18/2001 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) THIS INSPECTION IS FOR OVENS IN BAKERY AND DELI.
12/20/2001 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
12/20/2001 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*1.) MUST PROVIDE C.O. FOR COMBO WASTE & VENT SYSTEM @ VENTS. 2.) MUST PROVIDE DRAIN FOR BACKFLOW PREVENTER @ SODA MACHINE. 3.) MUST HAVE ALL BACKFLOW PREVENTERS TESTED & CERTIFIED WITHIN BLDG. PRIOR TO FINAL INSP.4.) MUST USE DIRECTIONAL FITTINGS ON ALL CONTINUOUS WASTE. 5.) WOMENS H.C. WATER CLOSET MUST BE @ 18" FROM SIDE WALL AS PER APPROVAL ELEVATION DRAWING (ADA) SPEC. 6.) EXPOSE C.O. FOR PRODUCE SINK 7.) MENS WATER CLOSET DOSE NOT MEET MIN SIDE CLEARANCE OF 15" TO FROM SIDE WALL 8.) OTHER PLBG. CONTACTOR NOT FINISHED WITH RELOCATION OF SINK IN BAKERY. 9.) MUST CAULK ALL FIXTURES & DRINKING FOUNTAIN.
12/26/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) ALL CORRECTIONS HAVE BEEN MADE.3.) OK FOR C OF O. 4.) U.C.C. HAS BEEN GIVEN TO JOB SUPERINTENDENTS
12/27/2001 ENGINEERING - FINAL DROBERTS Approved
12/28/2001 PERMIT FINALED DWITT Approved
12/28/2001 FIRE SPKLR - FINAL FIRE Approved
12/28/2001 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*
12/28/2001 ELECTRIC - TEMPORARY SERVICE MCAPISTR Approved
12/28/2001 ELECTRIC - CABLE DROP MCAPISTR Approved
12/28/2001 ELECTRIC - ABOVE CEILING MCAPISTR Approved IVRS - Inspection 0000*
12/28/2001 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*
12/28/2001 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection 0000*
12/28/2001 ELECTRIC - UFER MCAPISTR Approved
12/28/2001 BUILDING - FINAL DWITT Approved
12/28/2001 SHEET ROCK NAILING DWITT Approved
12/28/2001 BUILDING ABOVE CEILING DWITT Approved
12/28/2001 ROOF NAILING DWITT Approved
12/28/2001 EXT METAL CLIPS/EXT SHEATHING DWITT Approved
12/28/2001 REINFORCED MASONRY PRE-GROUT DWITT Approved

Documents

File Name Document Type  
T01CM03758_001.TIF CONSTRPLANS VIEW
T01CM03758_002.TIF CONSTRPLANS VIEW
T01CM03758_003.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
None DOCUMENTS VIEW
C OF O_12-31-2001.TIF CERT OF OCC VIEW
SITE PLAN_12-05-2001.TIF CERT OF OCC VIEW