Permit: T01CM03758

Parcel: 13338005E


Addresses:

10380 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM03758

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) MUST PROVIDE C.O. FOR COMBO WASTE & VENT SYSTEM @ VENTS. 2.) MUST PROVIDE DRAIN FOR BACKFLOW PREVENTER @ SODA MACHINE. 3.) MUST HAVE ALL BACKFLOW PREVENTERS TESTED & CERTIFIED WITHIN BLDG. PRIOR TO FINAL INSP.4.) MUST USE DIRECTIONAL FITTINGS ON ALL CONTINUOUS WASTE. 5.) WOMENS H.C. WATER CLOSET MUST BE @ 18" FROM SIDE WALL AS PER APPROVAL ELEVATION DRAWING (ADA) SPEC. 6.) EXPOSE C.O. FOR PRODUCE SINK 7.) MENS WATER CLOSET DOSE NOT MEET MIN SIDE CLEARANCE OF 15" TO FROM SIDE WALL 8.) OTHER PLBG. CONTACTOR NOT FINISHED WITH RELOCATION OF SINK IN BAKERY. 9.) MUST CAULK ALL FIXTURES & DRINKING FOUNTAIN.
11/17/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*
11/07/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM FOR UNISEX H.C. RESTROOM IS OK 2.) OVERHEAD WATER DISTRIBUTION OK 3.) OK FOR DRYWALL 4.)
FLOOR SINKS FOR PRODUCE & MEAT AREA ARE OK.
10/31/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM WATER TEST FOR DELI & BAKERY AREA OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL UPON BLDG. INSPECTION APPROVAL. 4.) NOTE MUST STRAP ALL HORIZONTAL VENTS EVERY 4'-0"
10/30/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) MUST PROVIDE WATER TEST ON WASTE & VENT SYSTEM ALL THE WAY THRU ROOF. 2.) DO NOT COVER.
10/29/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION.
10/25/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*ALL WATER PIPE MUST HAVE LINE PRESSURE AT TIME OF INSPECTION.
10/23/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) THIS INSPECTION INCLUDES 17 FLOOR SINKS IN FREEZER BOX AREA 2.) FLOOR DRAIN IN PRODUCE PRODUCE WORK ROOM OK.
10/19/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) THIS APPROVAL INCLUDES 2 FLOOR SINKS IN PRODUCE WORK ROOM 2.) 7 FLOOR SINKS IN BAKERY 3.) 11 FLOOR SINK IN DELI.
10/18/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*AS NOTED OR PLAN.
10/16/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
10/15/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*
10/12/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
10/08/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
10/05/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*PARTIAL PRODUCE WORK AREA.
10/04/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*P-1 3005 FOR MEZZANINE 2 TWO 3/4 "COPPER WATERS FOR ICE MACHINES INSIDE MAIN ENTRANCE.
10/03/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) THIS INSPECTION IS FOR RM #134 ONLY 4.) OK FOR DRYWALL IN THIS AREA UPON BLDG. INSPECTORS APPROVAL.