Permit: T01CM03707
Permit Details
Apply Date:
07/30/2001
Applicant:
CAVALLINO CONSTRUCTION
Description:
DUPLEX:TD#14-97-71
Contractors:
- CAVALLINO CONSTRUCTION
Permit Reviews
Permit Number - T01CM03707
Permit Status: C of o
Permit Description: DUPLEX:TD#14-97-71
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/12/2001 | REVISION | 12/31/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03707
Permit Description: DUPLEX:TD#14-97-71
Total Completed Inspections - 29
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT OF BLDG. ONLY 3.) OK TO BACKFILL TRENCH. |
08/09/2001 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) FINAL CONNECTION OF WATER SERVICE FROM METER TO BLDG SERVICE IS OK 2.) OK TO BACKFILL TRENCH. |
08/14/2001 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
08/14/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
08/15/2001 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000*OK 2 COPPER UFER NO PLANS ON SITE. |
08/21/2001 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1.) REVISED & APPROVED DRAWING FOR SITE SEWER IS OK. |
09/14/2001 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection 0000* |
09/17/2001 | ELECTRIC - TEMPORARY SERVICE | RMAJUTA | Approved | IVRS - Inspection 0000*1.) SUPPORT GFI RECEPTACLE UNDER SERVICE OK TO CLEAR OWNER METER FOR TEMP CONST POWER SUBJECT TO ALL OTHER INSPECTORS SIGN OFF. |
09/20/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
09/20/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
09/25/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
09/25/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
09/25/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) PEX PIPING OK PRESSURE TEST OK 3.) GAS PRESSURE TEST OK PIPING OK 4.) OK TO COVER WALLS OK TO COVER CEILING 5.) CLOSET FLANGES OK. |
10/02/2001 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
10/02/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) WILL CHECK CONDENSATE TERMINATION ON FINAL 2) OK FOR SHEET ROCK |
10/05/2001 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
10/05/2001 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
10/05/2001 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/05/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/10/2001 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
10/10/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
10/16/2001 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
12/18/2001 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK TO CLEAR TEMP POWER FOR TEST. UNITS, 1,2,3,4, |
01/11/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
01/11/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
01/14/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
01/23/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
01/24/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* |
01/29/2002 | PERMIT FINALED | DSANTACR | Approved |