Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
MULTI FAMILY NEW
Address NEW:
472 W 21ST ST #01
Apply Date:
07/09/2001
Applicant:
POSTER FROST
Description:
TRIPLEX:TD#14-41-33
Contractors:
  • GRANVILLE CONSTRUCTORS INC ,

Permit Reviews

Permit Number - T01CM03366
Permit Status: Final
Permit Description: TRIPLEX:TD#14-41-33
Start Date Submittal Complete Date Status  
07/09/2001 RESIDENTIAL BLDG/ZONING/FLOOD 07/09/2001 STOPPED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T01CM03366
Permit Description: TRIPLEX:TD#14-41-33
Total Completed Inspections - 25
Date Description Inspector Results Comments
12/07/2001 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*1.)NOT READY OF INSPECTION 8:00 AM 2.) THIS IS AN "F" MODEL. 3.) ABS DWV UNDERGROUND OK WATER TEST ONE RISER TO TEN FEET OK 4.) OK TO BACKFILL.
12/19/2001 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0000*
12/19/2001 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*1.) PLEASE MOVE UFER CONNECTOR ONTO SINGLE RE BAR.
12/27/2001 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection 0000*
01/03/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*1.) ABS TO SDR TRANSITION OK 2.) OK TO COVER.
01/24/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
04/17/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
05/13/2002 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
05/13/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*
05/14/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
05/17/2002 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
05/17/2002 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
05/19/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
05/20/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) COPPER WTER OK PRESSURE TEST OK 3.) CLOSET FLANGES OK 4.) TUBS OK. 5.) OK TO COVER ALL AREAS.
05/22/2002 ELECTRIC - CABLE DROP RMAJUTA Approved IVRS - Inspection 0000*APPROVED OK TO CLEAR.
05/29/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
07/16/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*
08/30/2002 PLUMBING - FINAL RMYERS Approved LOCATE LEAK IN WALL OR CEILING AND REPAIR HAVE WATER ON FOR FINAL.
09/06/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
09/09/2002 ELECTRIC - UNDERGROUND RMAJUTA Approved IVRS - Inspection 0000*APPROVED OK TO CLEAR 1,2,3, FOR TEMP POWER.
09/17/2002 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*
09/17/2002 ELECTRIC - SERVICE RELOCATION JORTA Approved
09/24/2002 PERMIT FINALED LHANLY Approved
09/24/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
09/24/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved