Permit: T01CM03288
Permit Details
Apply Date:
07/02/2001
Applicant:
RODNEY LANE MACKEY
Description:
NEW:TOWNHOUSE & PORCH
Contractors:
- OLLANIK CONSTRUCTION
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03288
Permit Description: NEW:TOWNHOUSE & PORCH
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2002 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/16/2002 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK #4 TO REBAR |
| 04/16/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* OK 3/4" PVC UNDER SLAB. |
| 04/25/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/16/2002 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/31/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/09/2002 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 11/13/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/15/2002 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000*OK CABLE DROP ONLY. |
| 12/03/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000* OK ROUGH ELECTRIC. |
| 12/13/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/16/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* IMC 2000 504 1.) SEC 504.6.1. MAX LENGTH 25' REDUCE 2.5 FT. FOR EACH 45 ELL, 5FT. FOR EA. 90 BEND. HAVE ARCHITECT ADDRESSS ISSUE. 2.) 5" DRYER VENT RUNNING HORIZONTAL IN FURRED AREA CAUSING CONJESTION AT SUPPLY/RETURN MAIN RUNS. CIRCUMFRENCE OF FLEX DUCT RED BY 50% AT BEND W/5" DRYER DUCT IN PLACE. |
| 12/31/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 01/21/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*THIS UNIT APPROVED ON 1/21/03 BY RMYERS. |
| 01/22/2003 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/11/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/05/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 3/6/03 AT 9:15AM OK TO CLEAR |
| 03/05/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | |
| 03/07/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*OUTSIDE SECTIONS NOT FUSED. |
| 03/13/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*NO GAS TO THIS UNIT. 2.) YARDWATER COMPLETE PRESSURE TEST OK TRANSITON FITTINGS OK TO OK TO COVER. |
| 03/20/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) SEWER/HCS APPROVED ON 6/6/01 BY J STANLEY 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 03/20/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* 1.) PROVIDE INSPECTION HISTORY FOR SEWER FROM 2 WAY CLEAN OUT TO SUMP, AND FROM SUMP TO TIE-IN AT SEWER MAIN. 2.) CITY DOES NOT INSPECT SEPTIC SYSTEMS, SUBJECT TO PIMA COUNTY WASTEWATER 3.) INSTALL ALL FIXTURES BEFORE CALLING IN FINALS. |
| 03/20/2003 | SEPTIC - SYSTEM | RMYERS | Approved | |
| 03/20/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/20/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0999* |
| 03/21/2003 | PERMIT FINALED | AQUIROZ | Approved | |
| 03/21/2003 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000*OK C OF O. |
| 03/21/2003 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |