Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2003 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection 0000*MAKE SURE ELECTRICIAN ETC. CONTINUE TO MAINTAIN PROPER CLEARANCE TO FRONT OF FAN COIL. | |
| 01/30/2003 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*MAINTAIN CLEAR ACCESS TO FRONT OF AIR HANDLER. ELECT HI VOLTAGE. CONDENSATE ECT. SPACE NEEDS PERM. LIGHT FIXTURES. |
|
| 12/16/2002 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* IMC 2000 504 1.) SEC 504.6.1. MAX LENGTH 25' REDUCE 2.5 FT. FOR EACH 45 ELL, 5FT. FOR EA. 90 BEND. HAVE ARCHITECT ADDRESSS ISSUE. 2.) 5" DRYER VENT RUNNING HORIZONTAL IN FURRED AREA CAUSING CONJESTION AT SUPPLY/RETURN MAIN RUNS. CIRCUMFRENCE OF FLEX DUCT RED BY 50% AT BEND W/5" DRYER DUCT IN PLACE. |
|
| 12/05/2002 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* 1.) CHECK DRYER VENT CRIMPED ENDS GO WITH FLOW OF AIR. 2.) MORE PROGRESS NEEDS TO BE COMPLETED IN BASEMENT AIR HANDLER LOCATION. PROVIDE PROPER CLEARANCE FOR SERVICE AND ACCESS. |