Permit: T01CM03153
Permit Details
Apply Date:
06/25/2001
Applicant:
RODNEY MACKEY
Description:
NEW:TOWNHOME & PORCH
Contractors:
- OLLANIK CONSTRUCTION
Permit Reviews
Permit Number - T01CM03153
Permit Status: C of o
Permit Description: NEW:TOWNHOME & PORCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/06/2002 | REVISION | 02/07/2002 | COMPLETED |
| 06/25/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 10/01/2001 | COMPLETED |
| 09/05/2002 | REVISION | 09/10/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM03153
Permit Status: C of o
Permit Description: NEW:TOWNHOME & PORCH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/25/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03153
Permit Description: NEW:TOWNHOME & PORCH
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2001 | REINFORCED MASONRY PRE-GROUT | EMONAHAN | Approved | IVRS - Inspection 0000$1ST @ BOND BEAM. |
| 01/23/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 02/08/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/08/2002 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 05/08/2002 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK #1/0 TO 2 GROUNDRODS OK CABLE DROP ONLY. |
| 05/15/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 05/15/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/15/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/16/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*OK ROUGH ELECTRICAL |
| 05/29/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/31/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 06/20/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 06/20/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 08/22/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/22/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000* OK FINAL SUBJECT TO OTHER INSPECTIONS. |
| 08/22/2002 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000*NO GAS AT THIS TIME CAULK SLEEVS. AS BUILD FOR SITE WATER. INSTALL CO COVER AT BAR SINK |
| 09/06/2002 | PERMIT FINALED | AMATHIES | Approved | |
| 09/06/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/06/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | |
| 09/09/2002 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000* |
| 09/09/2002 | FIRE - FINAL | LTHOMAS | Approved | |
| 09/09/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 09/10/2002 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 09/10/2002 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000*FINAL OK CARD GIVEN TO LEE |