Permit: T01CM01835
Permit Details
Apply Date:
04/17/2001
Applicant:
JESUS FLORES
Description:
ADDITION:BEDROOM/BATH
Permit Reviews
Permit Number - T01CM01835
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/17/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 05/21/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM01835
Permit Status: Final
Permit Description: ADDITION:BEDROOM/BATH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/17/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM01835
Permit Description: ADDITION:BEDROOM/BATH
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2001 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | STEM WALL/RETAINING WALL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) RASIE REBAR 3" TO EARTH |
| 09/04/2001 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | |
| 09/04/2001 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 09/24/2001 | ELECTRIC - SERVICE RELOCATION | HPEDROZA | Approved | IVRS - Inspection 0999* |
| 09/24/2001 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 09/24/2001 | FRAMING | HPEDROZA | Approved | / 1) MISSING A.B.'S AT SILL PLATE WITHIN 12" OF SPLIT 2) COMPLY WITH DETAIL 6A3 3) SEE INSPECTION 9/13/01 |
| 09/24/2001 | ROOF NAILING | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 09/24/2001 | EXT METAL CLIPS/EXT SHEATHING | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 09/26/2001 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) WHAT SIZE FLEX GAS LINE DID YOU INSTALL, CANNOT FIND ID ON PIPE? 2) YOU NEED STRIKER PLATE AT EXTERIOR WALL NORTH TOP PLATE ALSO NEXT TO INSIDE DOOR, TO FURNACE ROOM STRIKING PLATE DOES NOT COVER PIPE 3) YOU MENTIONED A NEW UNIT FOR THE HOUSE, WHAT KIND OF UNIT? GAS? ELECT? 4) PROTECT BATH LAV VERTICAL DRAIN AT BANG PLATE 5) COMBUSTIBLE/RELIEF AIR FOR FURNACE WATER HEATER WHERE IS IT 6) THERE SHOULD HAVE BEEN A WEATHER BARRIER INSTALLED AT EXTERIOR WALLS, WHAT ARE YOU GOING TO USE NOW? 7) DON'T INSULATE UNTIL ALL TRADES ARE COMPLETE AND INSPECTED 8) GAS TEST IS HOLDING |
| 12/05/2001 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) FLEX GAS LINE HAS NO ID FOR MANUFACTURER, TRAC PIPE SPEC. BOOK LEFT ON SITE 2) NEED COMBUSTION, RELIEF DUCT FOR WATER HEATER. 3) IRC ALLOW WATER HEATER IN BEDROOM WITH RESTRICTIONS 2406 303.3 EXCEPTION #5 SELF CLOSING, WEATHER STRIPPED DOOR, DEDICATED ROOM, SOLID CORE DOOR 2) A.B.'S LAV. NEED BANG PLATES 3) GAS PIPE NEED TO BE PROTECTED |
| 12/21/2001 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 12/21/2001 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 01/17/2002 | PERMIT FINALED | RFREIDIN | Approved | |
| 01/17/2002 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 01/17/2002 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 01/17/2002 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 01/17/2002 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |