Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/13/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) GROUNDING SYSTEM IS DISCONNECTED (RECONNECT ASAP) 2) NEED GAS DEMAND FOR HOUSE, LENGTHS OF PIPE RUNS 3) HOLES CUT IN 2 X RAFTERS TO BIG, TO CLOSE TENSION SIDE OF RAFTER, SHEET TO EXPLAIN LEFT WITH PLAN 4) LEAVE FLEX GAS LINE INSTALLATION INSTRUCTIONS ON SITE 5) EXISTING BATHROOM WILL NEED AND EXHASUT FAN 6) TAKE THE WEIGHT OF 2 X 4 WALL (AT REAR DOOR) NO HEADER INSTALLED 7) NO GRD WATER BOND, GAS BOND RISER AT SERVICE PANEL 8) NEED A GAS PRESSURE TEST 9) ALL TRADES REQUIRED TO BE COMPLETE/APPROVED BEFORE FRAMING CAN BE APPROVED |