Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
6334 E CALLE CAPPELA
Apply Date:
04/04/2001
Applicant:
AGUILAR GERARDO J & GERALDINE V
Description:
ADDITION:BEDROOM/BATH/FAMILY ROOM

Outstanding Activity Conditions

Permit Number - T01CM01604
Permit Status: Expired
Permit Description: ADDITION:BEDROOM/BATH/FAMILY ROOM
Total Outstanding Activity Conditions - 1
Date Name
04/04/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01CM01604
Permite Description: ADDITION:BEDROOM/BATH/FAMILY ROOM
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
U VALUE FOR WINDOW N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - CABLE DROP N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
02/12/2002 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE PIPE DIAGRAM LEFT ON SITE 2) CHANGE SECTION OF PIPE AT 90 DEGREE ANGLE ENTERING THE HOUSE FROM 1" TO MINIMUM 1 1/4" TO 2ND TEE

Completed Inspections

Permit Status: Expired
Permit Number: T01CM01604
Permit Description: ADDITION:BEDROOM/BATH/FAMILY ROOM
Total Completed Inspections - 13
Date Description Inspector Results Comments
06/13/2001 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
07/02/2001 PLUMBING - GAS PRESSURE TEST BSTEVENS Approved IVRS - Inspection 0000*
08/28/2001 ELECTRIC - SERVICE UPGRADE RFREIDIN Approved IVRS - Inspection 0000*
08/28/2001 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
09/07/2001 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*/ NOTE: POST FTGS FOR CARPORT, REAR PORCH-OK
12/14/2001 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/14/2001 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/14/2001 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/14/2001 FRAMING RFREIDIN Approved 1) ADD BLOCKS UNDER GLU/LAM BEAM AT EXISTING WALL SUPPORT (VERTICAL BLOCK) 2) AT FRONT BEDROOM BROKEN 2 X 10 RAFTER, TRY BLOCKING ON EACH SIDE IT GOES 1/2 UNDER FIREPLACE AND 1/2 EXTENDING OUT ON THE HEARTH SEE FIG 13 INSTRUCTIONS, YOU NEED 2" CLEARANCE TO COMBUSTIBELS AT FLUE CUT BACK WOOD THATS CLOSER, SECURE ROMEX TO/WALL INSIDE CHASE 4) CHECK ALL PIPES AND WIRES FOR SHEETROCK NAIL PROTECTION 5) FINISH FRAMING AT FIREPLACE, BLOCK OFF TOP OF CHASE, FIRE STOP 6) GAS LINE NEEDS TO BE SIZE AND DON'T HAVE TIME TODAY CAN DO IT AT NEXT INSPECTION 7) COULD SOMEONE WITH THIS JOB KNOWLEDGE MEET WITH ME AT NEXT INSPECTION, I HAVE SOME QUESTIONS 8) NEED BTU RATINGS FOR ALL ACTUAL GAS APPLIANCES TO BE INSTALLED 8) ALL GLAZING NOT INSTALLED YET 9) WATER LINE HOLDING PRESSURE 10) NEED GAS PRESSURE TEST
12/14/2001 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
01/11/2002 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
01/11/2002 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
02/22/2002 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*