Permit: T01CM01527
Permit Details
Apply Date:
03/29/2001
Applicant:
R A S BUILDERS
Description:
TI:OFFICE
Architects:
- SAYLER-BROWN, THOMAS
Permit Reviews
Permit Number - T01CM01527
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/29/2001 | 3RD PARTY COMMERCIAL TI | 04/24/2001 | COMPLETED |
04/25/2001 | REVISION | 05/01/2001 | COMPLETED |
05/02/2001 | REVISION | 05/02/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM01527
Permit Description: TI:OFFICE
Total Completed Inspections - 17
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
04/25/2001 | FRAMING | EMONAHAN | Approved | IVRS - Inspection 0000* |
04/25/2001 | EXCAVATION/LAYOUT REBAR & ZON | EMONAHAN | Approved | IVRS - Inspection 0000$ @ W SIDE |
05/08/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
05/08/2001 | SHEET ROCK NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
05/23/2001 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection 0000* |
06/05/2001 | FIRE SPKLR - FINAL | FIRE | Approved | |
06/11/2001 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*1)PROVIDE A FITTING IN SECONDARY DRAIN ALL UNITS OUTLETS.2)PROVIDE PROPER ACCESS TO AIR HANDLER IN CONFERENCE ROOM.WILL CHECK ON FINAL.3)MOVE ALL THREAD AND UNISTRUT TOWARD END OF UNIT IN KITCHEN. OK TO COVER CEILING.LEAVE OUT TILES IN FRONT OF AIR HANDLERS. |
07/11/2001 | PLUMBING - FINAL | JSTANLEY | Approved | PLEASE NOTE OVER RIM COFFEMAKERS INSTALLED AT THIS TIME. |
07/11/2001 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | |
07/11/2001 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000*ABOVE CEILING OK ABOVE CEILING. |
08/31/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
08/31/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
08/31/2001 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000*RIDGE POINT TO LABEL LAST 3 HP UNIT IN PANEL A. |
08/31/2001 | ELECTRIC - TEMPORARY POLE | RMAJUTA | Approved | |
08/31/2001 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | |
08/31/2001 | BUILDING - FINAL | EMONAHAN | Approved | IVRS - Inspection 0000* |