Permit: T01CM00843
Permit Details
Apply Date:
02/21/2001
Applicant:
SHAW, RALPH R
Description:
NEW:RETAIL
Architects:
- SHAW, RALPH R
Contractors:
- BARCLAY GROUP INC ,
Permit Reviews
Permit Number - T01CM00843
Permit Status: C of o
Permit Description: NEW:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2002 | REVISION | 01/23/2002 | COMPLETED |
02/21/2001 | COMMERCIAL NEW | 06/18/2001 | COMPLETED |
02/21/2001 | SITE | 08/17/2001 | COMPLETED |
08/30/2001 | REVISION | 09/05/2001 | COMPLETED |
11/26/2001 | REVISION | 12/05/2001 | COMPLETED |
12/19/2001 | REVISION | 12/21/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM00843
Permit Status: C of o
Permit Description: NEW:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/02/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM00843
Permit Description: NEW:RETAIL
Total Completed Inspections - 45
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2001 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000*1-#4 COPPER UFER TIED TO REBAR FOR GENERATOR 1 #3/0 COPPER UFER 20' LONG BLD SERVICE 3/0 |
09/07/2001 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | 1.) 2" COPPER FROM METER TO BLDG OK 2.) COPPER STUBBED THROUGH WALL OK PRESSURE TEST OK 3.) OK TO BACKFILL. |
09/10/2001 | ELECTRIC - TEMPORARY POLE | JORTA | Approved | IVRS - Inspection 0000*TEMP POLE PLEASE CLEAR. |
10/04/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS MODIFICATION TO PLAN AT BEER CASE OK WATER TEST OK OK TO COVER. 2.) THIS COMPLETE THE UNDERGROUND INSIDE THE STORE. |
10/17/2001 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000*MAIN SALER FLOOR COMPLETE. |
11/16/2001 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
11/19/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*1.) HCS INTERCEPTOR AND SAMPLER BOX OK OK TO COVER. |
11/19/2001 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
12/13/2001 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000*EXTERIOR SOFFITS AND EXTERIOR APPROVED. |
12/14/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* |
12/14/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
12/19/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) PRODUCE BAKERY AND MEAT AREAS OK TO COVER WALLS 2.) REMEMBER ALL SINKS REQUIRE CLEAN OUTS SPEC'S REQUIRE CLEAN OUTS AT THE BASE OF ALL STACKS. |
12/19/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000*WALL IN MEAT PREP AND BAKERY DELI APPROVED. |
12/28/2001 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
12/28/2001 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000* |
12/28/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) OK FOR TEMP POWER 2.) ROUGH GAS PIPING OK PRESSURE TEST MED PRESS OK 3.) DO NOT PAINT GAS PIPING UNTIL INSPECTED. |
12/28/2001 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
12/28/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000*PARTIAL EXTERIOR CEILING LIDS INFILL OVER REFERS OK. |
12/28/2001 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
12/28/2001 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
12/31/2001 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | GROUNDING BUSHING AND BONDING JUMPER REQUIRED AT ALL NIPPLE FOR SERVICE ENTRANCE RACEWAY BONDING WILL NEED APPROVED REVISION TO MDP. CHANGE IN WIRE SIZE AND BREAKER RATINGS. |
01/08/2002 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
01/08/2002 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection 0000* |
01/08/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
01/14/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING OK 2.) OK FOR TILE ETC. |
01/24/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
01/28/2002 | BOILER FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*REFRIGERANT HEAT ONLY AT COMPRESSOR LOCATIONS. |
01/28/2002 | BOILER - AIR TANK | CWILLIAM | Approved | |
01/28/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
01/30/2002 | SIGN - FINAL | JYBARRA | Approved | |
02/22/2002 | PERMIT FINALED | AMATHIES | Approved | |
02/22/2002 | HEALTH DEPT - FINAL 724-7908 | DTHOMAS | Approved | |
02/22/2002 | FIRE - FINAL | LTHOMAS | Approved | |
02/22/2002 | FIRE - HYDRANTS | LTHOMAS | Approved | |
02/22/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
02/22/2002 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
02/22/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
02/22/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
02/22/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | |
02/22/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
02/22/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
02/22/2002 | PLUMBING - FINAL | RMYERS | Approved | |
02/22/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
02/22/2002 | ELECTRIC - CABLE DROP | JORTA | Approved | |
02/22/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |