Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address NEW:
2621 N ESTRELLA AV 06
Apply Date:
02/08/2001
Applicant:
QUATROVEST INC ,
Description:
APARTMENTS: BLDG 6
Contractors:
  • QUATROVEST INC

Permit Reviews

Permit Number - T01CM00637
Permit Status: C of o
Permit Description: APARTMENTS: BLDG 6
Start Date Submittal Complete Date Status  
02/08/2001 COMMERCIAL NEW 04/27/2001 COMPLETED Review Details
05/08/2001 REVISION 05/08/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM00637
Permit Description: APARTMENTS: BLDG 6
Total Completed Inspections - 27
Date Description Inspector Results Comments
04/25/2001 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection 0000*
04/25/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000*
05/22/2001 ROOF NAILING EMONAHAN Approved IVRS - Inspection 0000*
05/31/2001 U VALUE FOR WINDOW EMONAHAN Approved IVRS - Inspection 0000*
06/01/2001 EXT METAL CLIPS/EXT SHEATHING EMONAHAN Approved IVRS - Inspection 0000*
06/09/2001 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection 0000*
06/11/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
06/15/2001 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*
06/19/2001 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
06/20/2001 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000* OK SUFFITS
06/22/2001 STUCCO MESH EMONAHAN Approved IVRS - Inspection 0000*
06/26/2001 SHEET ROCK NAILING EMONAHAN Approved INSTALL SCREWS WHERE INDICATED
07/23/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
07/24/2001 ELECTRIC - TEMPORARY POLE RHOLLAND Approved IVRS - Inspection 0999*
07/24/2001 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection 0000*
07/25/2001 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection 0000*1.) 9:25 AM NOT READY 2.) 11:30 AM NOT READY 3.) 1:00 PM TEST & NEW HCS OK TO BACKFILL.
08/27/2001 NPPO - FINAL PGILBERT Approved
08/27/2001 MECHANICAL - FINAL CWILLIAM Approved
08/27/2001 BUILDING - FINAL EMONAHAN Approved IVRS - Inspection 0000*
08/31/2001 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*NOTES BLD # UNITS 6101 6102
09/18/2001 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*REVISED APPROVED PLAN ON JOB APPROVED 9/13/01 TO ELIMINATE EXPANSION TANK ALSO SITE SEWER & WATER REVISION ON JOB AT THIS TIME.
10/10/2001 LANDSCAPE - FINAL PGILBERT Approved OKAY FOR TEMPORARY C OF O. COMPLETE LANDSCAPING PER PLAN.
10/11/2001 SIGN - FINAL JYBARRA Approved
04/12/2002 ENGINEERING - FINAL DROBERTS Approved
04/17/2002 MECHANICAL - HOODS CWILLIAM Approved
05/03/2002 PERMIT FINALED LLOPEZ Approved
05/03/2002 RIGHT OF WAY - FINAL LLOPEZ Approved