Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM00442
Permit Details
Apply Date:
01/29/2001
Applicant:
SUNBURST HOMES
Description:
DUPLEX:TD#14-86-13
Contractors:
- YARBROUGH CONSTRUCTION COMPANY I
Permit Reviews
Permit Number - T01CM00442
Permit Status: Final
Permit Description: DUPLEX:TD#14-86-13
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/29/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 01/29/2001 | COMPLETED |
| 02/08/2001 | REVISION | 02/08/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM00442
Permit Description: DUPLEX:TD#14-86-13
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* OK TO BACK FILL |
| 04/12/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
| 05/15/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 05/15/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 05/15/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 05/15/2001 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 05/15/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* NOTE: BLACK TEE NOT APPROVED HORIZONTAL POSITION BELOW GRADE WATER TEST REQUIRED ON INTERMEDIATE NEED SUPPORT ON GAS PIPE OVER HEAD |
| 05/15/2001 | ROOF NAILING | DWITT | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/31/2001 | SHEET ROCK NAILING | DWITT | Approved | |
| 06/08/2001 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | |
| 06/08/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | |
| 06/08/2001 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 09/10/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 09/10/2001 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 09/12/2001 | PERMIT FINALED | LHANLY | Approved | |
| 09/12/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 09/12/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |