Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM00442
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* OK TO BACK FILL | |
| 03/09/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* 1) 1/4" PER FOOT SLOPE REQUIRED ON DRAINAGE PIPING 2) CHANGES OF DIRECTION FROM VERTICAL TO HORIZONTAL REQUIRE WYE BRANCH FITTING OR EQUIVILENT SWEEP INCLUDES WATER CLOSETS. 3) PLASTIC PIPE SHALL BE SUPPORTED FOR ITS ENTIRE LENGTH BRIDGING NOT ALLOWED. |