Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM00442

Parcel: 130050010

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T01CM00442

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/15/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000* OK TO BACK FILL
03/09/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999* 1) 1/4" PER FOOT SLOPE REQUIRED ON DRAINAGE PIPING 2) CHANGES OF DIRECTION FROM VERTICAL TO HORIZONTAL REQUIRE WYE BRANCH FITTING OR EQUIVILENT SWEEP INCLUDES WATER CLOSETS. 3) PLASTIC PIPE SHALL BE SUPPORTED FOR ITS ENTIRE LENGTH BRIDGING NOT ALLOWED.