Permit Details

Status:
Expired
Type:
COMMERCIAL ADDITION
Address:
1302 E PRINCE RD
Address NEW:
1302 E PRINCE RD
Apply Date:
01/04/2001
Applicant:
C AND N CONSTRUCTION INC ,
Description:
ADDITION:METAL BLDG FOR STORAGE
Contractors:
  • A MAX CONSTRUCTION ,

Permit Reviews

Permit Number - T01CM00053
Permit Status: Expired
Permit Description: ADDITION:METAL BLDG FOR STORAGE
Start Date Submittal Complete Date Status  
01/04/2001 COMMERCIAL NEW 03/15/2001 COMPLETED Review Details
01/05/2001 SITE 03/15/2001 COMPLETED Review Details
03/06/2002 REVISION 03/07/2002 COMPLETED Review Details
03/14/2002 REVISION 03/15/2002 COMPLETED Review Details
04/18/2001 SITE 06/19/2001 COMPLETED Review Details
04/18/2001 RESUBMITTAL 06/19/2001 COMPLETED Review Details
06/21/2001 SITE 07/10/2001 COMPLETED Review Details
06/21/2001 RESUBMITTAL 07/10/2001 STOPPED Review Details
07/11/2001 RESUBMITTAL 07/11/2001 STOPPED Review Details
09/12/2002 REVISION 09/19/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM00053
Permit Status: Expired
Permit Description: ADDITION:METAL BLDG FOR STORAGE
Total Outstanding Activity Conditions - 5
Date Name
01/04/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
06/07/2001 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
06/07/2001 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
06/07/2001 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
06/07/2001 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01CM00053
Permite Description: ADDITION:METAL BLDG FOR STORAGE
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
ROOF NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
PLUMBING - GAS PRESSURE TEST N/A Not Inspected
PLUMBING - PROGRESS N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
FIRE SPKLR - OH PIPING & HYDRO N/A Not Inspected
FIRE SPKLR - FINAL N/A Not Inspected
FIRE - FINAL N/A Not Inspected
SIGN - FINAL N/A Not Inspected
NPPO - FINAL N/A Not Inspected
04/03/2002 PLUMBING - ABOVE CEILING N/A Not ready for Inspection IVRS - Inspection 0000*
12/11/2001 PLUMBING - ROUGH, SOIL N/A Partial Approval IVRS - Inspection 0000*SUBJECT TO APPROVED REVISED PLAN PLUMBER INSTALLED 3 PLAN CALLS FOR 4"
12/18/2002 BUILDING PRE-SLAB N/A Not ready for Inspection IVRS - Inspection 0000*

Completed Inspections

Permit Status: Expired
Permit Number: T01CM00053
Permit Description: ADDITION:METAL BLDG FOR STORAGE
Total Completed Inspections - 11
Date Description Inspector Results Comments
07/10/2001 LANDSCAPE - FINAL JLinvill Approved Check for existing border required west of expansion area.
12/11/2001 STEM WALL/RETAINING WALL EMONAHAN Approved
04/04/2002 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*TEST OK WASTE VENTS & WATER TEST OK ON GAS LINE PLEASE PROVIDE REVISED PLAN BEFORE APPROVED IS GIVEN
04/04/2002 FRAMING AMATHIES Approved
04/08/2002 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*1.) SECONDARY DRAIN CANNOT DRAIN INTO THE SEWER VENT MUST BE RAN TO A CONSPICUOUS LOCATION. WILL CHECK ON FINAL. OK TO SHEET ROCK.
04/16/2002 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
07/12/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
10/01/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*
10/01/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved
10/02/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved
12/18/2002 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*