Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
8710 E BEARS PATH RD
Apply Date:
06/09/2000
Applicant:
AFFORDABLE PLUMBING
Description:
WATER LINE:REPLACEMENT
Contractors:
  • AFFORDABLE PLUMBING

Outstanding Inspections

Permit Status: Expired
Permit Number: T00PL01106
Permite Description: WATER LINE:REPLACEMENT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/13/2000 PLUMBING - FINAL N/A Correction Required ADDTL COMMS - 1. NO EXPOSED PVC ALLOWED 2. CAN NOT SCREW COPPER INTO PVC 90 DEGREE 3. OK TO BACKFILL TRENCH 4. WHAT IS BACKFLOW PREVENTER SERVING?
06/20/2000 PLUMBING - YARD WTR LINE/TEST N/A Correction Required ADDTL COMMS - 1. WATER HTR WILL REQUIRE A EXPANSION TANK TO PREVENT THERMAL EXPANSION DUE TO CLOSE SYSTEM BY BACKFLOW PERVENTER 2. NOTE: HOSE BIBS REQUIRE VACUMN BREAKERS