Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
2136 N MADELYN AV
Apply Date:
05/12/2000
Applicant:
ENHELDER DALE
Description:
REPLACE:GAS LINES

Completed Inspections

Permit Status: Final
Permit Number: T00PL00972
Permit Description: REPLACE:GAS LINES
Total Completed Inspections - 2
Date Description Inspector Results Comments
06/01/2000 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. WATER HTR MUST HAVE ENCLOSURE 3. WATER HTR P&T DRAIN MUST BE OF APPROVED MATERIAL CPVC, COPPER, GALVANIZED AND TERMINATE 6 A.F.F. 4. WATER DISTRIBUTION INSIDE OF DWELLING MUST BE OF APPROVED MATERIAL CPVC, COPPER OR PEX 5. CAN NOT HAVE 2 FLEX CONNECTORS CONNECTED TOGETHER AT DRYER 6. WATER HTR FLU VENT MUST BE MIN 5-0 FROM WATER HTR COLLAR TO FLU CAP TERMINATE 10 MIN. ABOVE ROOF 7. GAS CLEARANCE CARD WILL BE ISSUED AT FINAL NOTE: IF DBL WALL FLU VENT IS USED YOU MUST HAVE MIN 1 CLEARANCE AROUND VENT SINGLE WALL MIN 6 CLEARANCE
07/26/2000 PERMIT FINALED JMILITEL Approved